MétaCan
Menu
Back to cohort
Record W4287094858 · doi:10.1117/1.jbo.27.7.077001

Detection of hypoxia by near-infrared spectroscopy and pulse oximetry: a comparative study

2022· article· en· W4287094858 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueJournal of Biomedical Optics · 2022
Typearticle
Languageen
FieldMedicine
TopicOptical Imaging and Spectroscopy Techniques
Canadian institutionsInternational Collaboration On Repair DiscoveriesUniversity of British Columbia
FundersCanadian Institutes of Health ResearchInternational Collaboration on Repair DiscoveriesU.S. Department of Defense
KeywordsPulse oximetryMedicineHypoxia (environmental)OxygenationAnesthesiaPulse (music)Blood oxygenationOxygen saturationOxygenDetectorChemistry

Abstract

fetched live from OpenAlex

SIGNIFICANCE: Pulse oximetry is widely used in clinical practice to monitor changes in arterial oxygen saturation (SpO2). However, decreases in SpO2 can be delayed relative to the actual clinical event, and near-infrared spectroscopy (NIRS) may detect alterations in oxygenation earlier than pulse oximetry, as shown in previous cerebral oxygenation monitoring studies. AIM: We aim to compare the response of transcutaneous muscle NIRS measures of the tissue saturation index with pulse oximetry SpO2 during hypoxia. APPROACH: Episodes of acute hypoxia were induced in nine anesthetized Yucatan miniature pigs. A standard pulse oximeter was attached to the ear of the animal, and a transcutaneous NIRS sensor was placed on the hind limb muscle. Hypoxia was induced by detaching the ventilator from the animal and reattaching it once the pulse oximeter reported 70% SpO2. RESULTS: Twenty-four episodes of acute hypoxia were analyzed. Upon the start of hypoxia, the transcutaneous NIRS measures changed in 5.3 ± 0.4 s, whereas the pulse oximetry measures changed in 14.9 ± 1.0 s (p < 0.0001). CONCLUSIONS: Transcutaneous muscle NIRS can detect the effects of hypoxia significantly sooner than pulse oximetry in the Yucatan miniature pig. A transcutaneous NIRS sensor may be used as an earlier detector of oxygen saturation changes in the clinical setting than the standard pulse oximeter.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.285
Threshold uncertainty score0.432

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.322
Teacher spread0.307 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it