MétaCan
Menu
Back to cohort
Record W4288071910 · doi:10.4236/wjcd.2022.127042

Permanent Pacemaker Implantation in a Patient with Ventricular Fibrillation due to Spontaneous Coronary Artery Dissection: A Case Report

2022· article· en· W4288071910 on OpenAlexaboutno aff
Altamirano Alvaro, Moukabary Talal, Negar Faramarzi, Habibi Roshanak

Bibliographic record

VenueWorld Journal of Cardiovascular Diseases · 2022
Typearticle
Languageen
FieldMedicine
TopicCardiovascular Issues in Pregnancy
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineVentricular fibrillationCardiologyInternal medicineScadVentricular tachycardiaArtery dissectionCardiopulmonary resuscitationCoronary artery diseaseSudden cardiac deathDissection (medical)DefibrillationRight coronary arteryResuscitationSurgeryMyocardial infarctionCoronary angiography

Abstract

fetched live from OpenAlex

We present here the case of a 43-year-old female without any known past medical history who was brought into the emergency department (ED) by the emergency medical services (EMS) after receiving cardiopulmonary resuscitation (CPR) on the field. Per EMS, on arrival patient was found to be on ventricular fibrillation and was shocked 3 times. Patient had no past medical history. In the ED, EKG showed sinus rhythm and troponin was 23 which is slightly high compared to upper limit. Patient was taken to the cath lab immediately which showed small to medium caliber septal 1 branch severe mid segment disease with distal tapering suggestive of spontaneous coronary artery dissection. No stent was placed. Electrophysiology was consulted and an Implantable Cardioverter Defibrillator was placed. Spontaneous coronary artery dissection (SCAD) is a phenomenon where an epicardial coronary artery dissection occurs that is not related to atherosclerosis, trauma or iatrogenia. Patients with SCAD presenting with ventricular arrhythmias are not very common. In a Canadian registry analyzing 1056 patients with SCAD, only 84 of them presented with ventricular fibrillation (VF) or ventricular tachycardia (VT) and only 8 underwent ICD placement. They followed up the patients for 5 years and 8 patients suffered VT/VF. 5 of those 8 patients had VT/VF on initial SCAD presentation, and only 1 of them had undergone ICD insertion. There are no specific guidelines regarding ICD placement on patients with coronary artery dissection, but the AHA/ACC/HRS guidelines can help us make decisions. Our case underscores the importance of more prospective or retrospective studies to identify those patients with SCAD who would benefit from ICD placement for secondary prevention. The current guidelines for ventricular arrhythmias are an excellent tool for the electrophysiologist regarding the management of these arrhythmias in other specific scenarios but guidance on SCAD is still lacking.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: Case report
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.098
Threshold uncertainty score0.885

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.230
Teacher spread0.224 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueWorld Journal of Cardiovascular DiseasesSame topicCardiovascular Issues in PregnancyFrench-language works237,207