MétaCan
Menu
Back to cohort
Record W4288882039 · doi:10.5383/ijtee.15.02.010

Study on Adsorption Refrigeration System Using Activated Carbon-Ethanol as Working Pair

2019· article· en· W4288882039 on OpenAlexvenueno aff
I Made Astina, Ren Sokha, Prihadi Setyo Darmanto

Bibliographic record

VenueInternational Journal of Thermal and Environmental Engineering · 2019
Typearticle
Languageen
FieldEngineering
TopicAdsorption and Cooling Systems
Canadian institutionsnot available
FundersJapan International Cooperation Agency
KeywordsAdsorptionCoefficient of performanceRefrigerationCooling capacityMaterials scienceThermodynamicsWaste heatActivated carbonDesorptionWater coolingGas compressorChemistryChemical engineeringNuclear engineeringRefrigerantHeat exchangerOrganic chemistryEngineering

Abstract

fetched live from OpenAlex

The adsorption refrigeration system is an alternative refrigeration system powered by thermal source so that it is possible to use waste heat and solar energy. This paper reports the experiment of the ethanol-activated carbon (AC) as the adsorbateadsorbent pair. Experimental work was conducted with two adsorption beds as thermal compressor. Ethanol-AC pair can be operated with the heat source temperatures 90o C and 100o C for different heat sink temperature 20o C, 25o C and 30o C, respectively. The experimental result shows when temperature of the hot water 100o C and the cooling water temperature 30o C, the system give the higher coefficient of performance (COP) than another testing operation condition. Additionally, the COP of the system is varying a long operating in average 0.19 due to manually intermittent operation of both adsorption beds. The maximum adsorption capacity is 0.302 kg/kg·AC while the desorption temperature, desorption pressure and heating time of the adsorption bed are 85o C, 85.52 kPa and 80 minutes, respectively, and the cooling capacity is 23.61 kJ for a operating cycle. The experimental result proved that the ethanol-AC is suitable pair with the adsorption system for cooling application. It can be operated at low temperature driven heat source, and has an environmentally friendly behavior and the working pair is easy to be found in the commercial market.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.201
Teacher spread0.191 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Thermal and Environmental EngineeringSame topicAdsorption and Cooling SystemsFrench-language works237,207