Monitoring Arm Movements Post-Stroke for Applications in Rehabilitation and Home Settings
Bibliographic record
Abstract
Optimal recovery of arm function following stroke requires patients to perform a large number of functional arm movements in clinical therapy sessions, as well as at home. Technology to monitor adherence to this activity would be helpful to patients and clinicians. Current approaches to monitoring arm movements are limited because of challenges in distinguishing between functional and non-functional movements. Here, we present an Arm Rehabilitation Monitor (ARM), a device intended to make such measurements in an unobtrusive manner. The ARM device is based on a single Inertial Measurement Unit (IMU) worn on the wrist and uses machine learning techniques to interpret the resulting signals. We characterized the ability of the ARM to detect reaching actions in a functional assessment dataset (functional assessment tasks) and an Activities-of-Daily-Living (ADL) dataset (pizza-making and walking task) from 12 participants with stroke. The Convolutional Neural Network (CNN) and Random Forests (RF) classifiers had a Matthews Correlation Coefficient score of 0.59 and 0.58 when trained and tested on the functional dataset, 0.50 and 0.49 when trained and tested on the ADL dataset, and 0.37 and 0.36 when trained on the functional dataset and tested on the ADL dataset, respectively. The latter is the most relevant scenario for the intended application of training during a clinical visit for monitoring movements in the in-home setting. The classifiers showed good performance in estimating the time spent reaching and number of reaching gestures and showed low sensitivity to irrelevant arm movements produced during walking. We conclude that the ARM has sufficient accuracy and robustness to merit being used in preliminary studies to monitor arm activity in rehabilitation or home applications.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.002 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".