MétaCan
Menu
Back to cohort
Record W4293553580 · doi:10.1002/rcm.9388

Understanding the effect of spatial positioning of coated blade spray devices relative to the mass spectrometry inlet on different instrument platforms and its application to quantitative analysis of fentanyl and related analogs

2022· article· en· W4293553580 on OpenAlexaff
Daniel Rickert, Germán Augusto Gómez‐Ríos, Varoon Singh, Janusz Pawliszyn

Bibliographic record

VenueRapid Communications in Mass Spectrometry · 2022
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsChemistryMass spectrometryInletIon trapTriple quadrupole mass spectrometerQuadrupole ion trapAnalytical Chemistry (journal)ChromatographyMechanical engineeringTandem mass spectrometrySelected reaction monitoringEngineering

Abstract

fetched live from OpenAlex

RATIONALE: We evaluated the effect that the spatial positioning of coated-blade spray (CBS) devices with respect to the mass spectrometry (MS) inlet has when coupling to diverse MS platforms (i.e., triple quadrupole, linear ion trap and time of flight). Furthermore, as a proof of concept, we evaluated CBS-MS as a tool for quantitation of fentanyl and four analogues on said instruments. METHODS: Custom-made MS interfaces were made to accurately position the blade in front of the MS inlet. CBS devices, coated with hydrophilic-lipophilic balanced particles, were used for both the optimization of the CBS position and the quantitation of fentanyl and analogues in urine and plasma samples on all instruments. RESULTS: The SCIEX triple quadrupole instrument was the most sensitive to the position of the blade due to the presence of a curtain gas flowing laminarly out of the MS inlet. After optimization, the analytical capabilities of CBS on each instrument were assessed and the results obtained on both SCIEX and Waters platforms matched the performance obtained using a more advanced instrument by ThermoFisher Scientific. Furthermore, excellent figures of merit were attained for the quantitation of fentanyl and analogues on both triple quadrupole and linear ion trap platforms. CONCLUSIONS: We demonstrated that optimization of MS parameters on different instrument vendors and front ends, such as the position of the CBS tip regarding the MS inlet, is vital to exploit the full quantitative potential of this technology. Application of the technology to screen and quantify fentanyl and analogues showed great potential when considering its coupling with portable mass spectrometers for therapeutic drug monitoring and point-of-care applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.006
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.295
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueRapid Communications in Mass SpectrometrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207