MétaCan
Menu
Back to cohort
Record W4294706187 · doi:10.31399/asm.cp.itsc2006p1463

Metallic Fume Emission and Operator Exposure During WC-10%Co-4%Cr Spraying by HVOF

2006· article· en· W4294706187 on OpenAlexaff
J.-G. Legoux, J. Oberste Berghaus, C. Moreau

Bibliographic record

VenueThermal spray · 2006
Typearticle
Languageen
FieldEngineering
TopicAdvanced materials and composites
Canadian institutionsNational Research Council Canada
Fundersnot available
KeywordsThermal sprayingChrome platingHexavalent chromiumChromiumMetallurgyMaterials scienceCoatingPlating (geology)Cathodic protectionComposite materialAnodeChemistryElectroplating

Abstract

fetched live from OpenAlex

Abstract The increasing use of HVOF (high-velocity oxy-fuel) coatings to replace hard chrome plating was initially motivated by the environmental and health risks associated with hexavalent chromium (Cr6+) emissions during the plating process. Following performance optimization and proper coating selection, it has been found that the potential increase in performance and the cost/process-time reduction offered by the HVOF process often justifies its application. Recently, the use of Cr-containing alloys processed by HVOF has drawn attention to the potential release of Cr6+ during heating of metallic chromium. For instance a new California regulation for airborne toxic control measures to reduce emission of hexavalent chromium from thermal spraying is in preparation. The present study focused on monitoring operator exposure during the HVOF spraying of WC-10%Co-4%Cr. The spraying was performed using a JP-5000 HVOF gun in a spray room in which a ventilation flow rate of 10,000 scfm was imposed. Air sampling was taken in the spray room as well as in the adjacent control room in accordance with the NIOSH 7300 and 7600 standard methods. A portable sampler attached on the operator’s chest was also used to monitor the operator exposure during a typical workday. Results indicate that even though metallic fumes of Co and Cr are present in the spray room during spraying, the hexavalent form Cr6+ is not detected. It was concluded that an operator entering the spray room for a limited amount of time with the gun in operation would be exposed to only low fume levels that can still be reduced by wearing an appropriate respiratory mask.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.663

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.003
GPT teacher head0.180
Teacher spread0.177 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueThermal spraySame topicAdvanced materials and compositesFrench-language works237,207