MétaCan
Menu
Back to cohort
Record W4295780223 · doi:10.1007/s10439-022-03066-0

Consensus Head Acceleration Measurement Practices (CHAMP): Laboratory Validation of Wearable Head Kinematic Devices

2022· article· en· W4295780223 on OpenAlexaff
Lee F. Gabler, Declan A. Patton, Mark T. Begonia, R.W. Daniel, Ahmad Rezaei, Colin M. Huber, Gunter P. Siegmund, Tyler F. Rooks, Lyndia C. Wu

Bibliographic record

VenueAnnals of Biomedical Engineering · 2022
Typearticle
Languageen
FieldMedicine
TopicAutomotive and Human Injury Biomechanics
Canadian institutionsUniversity of British Columbia HospitalUniversity of British Columbia
Fundersnot available
KeywordsWearable computerComputer scienceKinematicsWearable technologySoftware deploymentData validationField (mathematics)Head (geology)Data collectionSimulationHuman–computer interactionSoftware engineeringEmbedded system

Abstract

fetched live from OpenAlex

Wearable devices are increasingly used to measure real-world head impacts and study brain injury mechanisms. These devices must undergo validation testing to ensure they provide reliable and accurate information for head impact sensing, and controlled laboratory testing should be the first step of validation. Past validation studies have applied varying methodologies, and some devices have been deployed for on-field use without validation. This paper presents best practices recommendations for validating wearable head kinematic devices in the laboratory, with the goal of standardizing validation test methods and data reporting. Key considerations, recommended approaches, and specific considerations were developed for four main aspects of laboratory validation, including surrogate selection, test conditions, data collection, and data analysis. Recommendations were generated by a group with expertise in head kinematic sensing and laboratory validation methods and reviewed by a larger group to achieve consensus on best practices. We recommend that these best practices are followed by manufacturers, users, and reviewers to conduct and/or review laboratory validation of wearable devices, which is a minimum initial step prior to on-field validation and deployment. We anticipate that the best practices recommendations will lead to more rigorous validation of wearable head kinematic devices and higher accuracy in head impact data, which can subsequently advance brain injury research and management.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.318
metaresearch head score (Gemma)0.406
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.318
Threshold uncertainty score0.841

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.3180.406
Meta-epidemiology (narrow)0.0020.002
Meta-epidemiology (broad)0.0020.004
Bibliometrics0.0110.006
Science and technology studies0.0050.005
Scholarly communication0.0080.006
Open science0.0130.008
Research integrity0.0080.006
Insufficient payload (model declined to judge)0.0040.007

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.127
GPT teacher head0.357
Teacher spread0.229 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueAnnals of Biomedical EngineeringSame topicAutomotive and Human Injury BiomechanicsFrench-language works237,207