MétaCan
Menu
Back to cohort
Record W4295900518 · doi:10.1002/mus.27720

<scp>Ultrasound‐guided</scp> motor unit scanning electromyography

2022· article· en· W4295900518 on OpenAlexfundno aff
Stuart Maitland, Julie Hall, Andrew McNeill, Ben Stenberg, Ian Schofield, Roger G. Whittaker

Bibliographic record

VenueMuscle & Nerve · 2022
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsnot available
FundersNIHR Newcastle Biomedical Research CentreMedical Research Council CanadaDepartment of Health and Social CareMedical Research CouncilNewcastle UniversityNational Institute for Health and Care Research
KeywordsMotor unitElectromyographyUltrasoundMotor unit recruitmentMedicineBiomedical engineeringUltrasound imagingPhysical medicine and rehabilitationComputer scienceAnatomyRadiology

Abstract

fetched live from OpenAlex

INTRODUCTION/AIMS: Measuring the spatial dimensions of a single motor unit remains a challenging problem, and current techniques, such as scanning electromyography (EMG), tend to underestimate the true dimensions. In this study we aimed to estimate more accurately the dimensions of a single motor unit by developing a clinically applicable scanning EMG protocol that utilizes ultrasound imaging to visualize and target a transect through the center of a single motor unit. METHODS: Single motor unit twitches in the tibialis anterior muscles of healthy volunteers were elicited via stimulation of the fibular nerve, visualized with ultrasound, and targeted with an intramuscular EMG electrode. The electrode was moved by hand in small steps through the motor unit territory. Ultrasound video output was synchronized to EMG capture, and the needle position was tracked at each step. RESULTS: Eight recordings from six participants were collected. The technique was quick and easy to perform (mean time, 6.1 minutes) with reasonable spatial resolution (mean step size, 1.85 mm), yielding motor unit territory sizes between 1.53 and 14.65 mm (mean, 7.15 mm). DISCUSSION: Ultrasound-guided motor unit scanning EMG is a quick and accurate method for obtaining a targeted motor unit transect. This combination of two readily available clinical tools provides insights into the dimensions and internal structure of the motor unit as a marker for neuromuscular conditions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.217
Teacher spread0.203 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueMuscle & NerveSame topicMuscle activation and electromyography studiesFrench-language works237,207