MétaCan
Menu
Back to cohort
Record W4296039174 · doi:10.1016/j.jvir.2022.07.032

Comparison of Bolus Versus Dual-Syringe Administration Systems on Glass Yttrium-90 Microsphere Deposition in an In Vitro Microvascular Hepatic Tumor Model

2022· article· en· W4296039174 on OpenAlexaff
Samuel Miller, Shaphan R. Jernigan, Robert J. Abraham, Gregory D. Buckner

Bibliographic record

VenueJournal of Vascular and Interventional Radiology · 2022
Typearticle
Languageen
FieldEngineering
Topic3D Printing in Biomedical Research
Canadian institutionsDalhousie University
FundersDivision of Electrical, Communications and Cyber SystemsNorth Carolina State UniversityNational Science Foundation
KeywordsMedicineMicrosphereBolus (digestion)Syringe driverGlass microsphereNuclear medicineDeposition (geology)Biomedical engineeringPerfusionSyringeSurgeryRadiology

Abstract

fetched live from OpenAlex

Purpose To utilize an in vitro microvascular hepatic tumor model to compare the deposition characteristics of glass yttrium-90 microspheres using the dual-syringe (DS) and traditional bolus administration methods. Materials and Methods The microvascular tumor model represented a 3.5-cm tumor in a 1,400-cm 3 liver with a total hepatic flow of 160 mL/min and was dynamically perfused. A microcatheter was placed in a 2-mm artery feeding the tumor model and 2 additional nontarget arteries. Glass microspheres with a diameter of 20–30 μm were administered using 2 methods: ( a ) DS delivery at a concentration of 50 mg/mL in either a single, continuous 2-mL infusion or two 1-mL infusions and ( b ) bolus delivery (BD) of 100 mg of microspheres in a single 3-mL infusion. Results Overall, the degree of on-target deposition of the microspheres was 85% ± 11%, with no significant differences between the administration methods. Although the distal penetration into the tumor arterioles was approximately 15 mm (from the second microvascular bifurcation of the tumor model) for all the cases, the distal peak particle counts were significantly higher for the DS delivery case (approximately 5 × 10 5 microspheres achieving distal deposition vs 2 × 10 5 for the BD case). This resulted in significantly higher deposition uniformity within the tumor model (90% for the DS delivery case vs 80% for the BD case, α = 0.05). Conclusions The use of this new in vitro microvascular hepatic tumor model demonstrated that the administration method can affect the deposition of yttrium-90 microspheres within a tumor, with greater distal deposition and more uniform tumor coverage when the microspheres are delivered at consistent concentrations using a DS delivery device. The BD administration method was associated with less favorable deposition characteristics of the microspheres.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.324
Teacher spread0.293 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Vascular and Interventional RadiologySame topic3D Printing in Biomedical ResearchFrench-language works237,207