MétaCan
Menu
Back to cohort
Record W4296161010 · doi:10.1113/ep090716

A single breath of nitric oxide does not alter pulmonary perfusion pressure

2022· article· en· W4296161010 on OpenAlexafffund
Andrew R. Brotto, Rhys I. Beaudry, Samira Rowland, Sean van Diepen, Michael K. Stickland

Bibliographic record

VenueExperimental Physiology · 2022
Typearticle
Languageen
FieldMedicine
TopicPulmonary Hypertension Research and Treatments
Canadian institutionsUniversity of Alberta
FundersCanadian Institutes of Health Research
KeywordsDiffusing capacityNitric oxidePulmonary Diffusing CapacityPulmonary arteryCardiologyPerfusionPlaceboInternal medicineMedicineLungAnesthesiaLung functionPathology

Abstract

fetched live from OpenAlex

New Findings What is the central question of this study? Is the amount of inhaled nitric oxide (NO) used during a diffusing capacity for inhaled NO manoeuvre sufficient to reduce pulmonary artery systolic pressure (PASP)? What is the main finding and its importance? These findings suggest that a single breath of inhaled NO does not change PASP, and combined with previous correlational work, further validates the use of the diffusing capacity for NO manoeuvre as a technique to determine pulmonary capillary blood volume and membrane diffusing capacity. Abstract The measurement of diffusing capacity is an important pulmonary function test to evaluate gas exchange. Using both carbon monoxide and nitric oxide (NO), the diffusing capacity for nitric oxide ( D L,NO ) technique allows for the partitioning of capillary blood volume and membrane diffusing capacity. However, inhaled NO is known to dilate pulmonary arterioles in both health and disease and therefore could alter the outcomes that the D L,NO technique aims to quantify. The purpose of the study was to determine if a D L,NO manoeuvre alters pulmonary perfusion pressure. Nine participants completed 12 simulated 10‐s breath‐hold D L,NO manoeuvres ( n = 6 placebo inhalations and n = 6 with 40 ppm NO; order randomized) during which tricuspid regurgitant jet velocity was recorded continuously using Doppler ultrasound to estimate pulmonary artery systolic pressure (PASP) as a surrogate for pulmonary perfusion pressure. The PASP was not different between the placebo and NO conditions ( P = 0.742). These data indicate that a single D L,NO manoeuvre does not alter PASP and therefore would not be expected to acutely alter pulmonary capillary blood volume or membrane diffusing capacity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.066
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.289
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueExperimental PhysiologySame topicPulmonary Hypertension Research and TreatmentsFrench-language works237,207