MétaCan
Menu
Back to cohort
Record W4300976763

The OxyMask™ development and performance in healthy volunteers

2008· article· en· W4300976763 on OpenAlexaboutno aff
James Paul, Horia Hangan, Julius Hajgato

Bibliographic record

VenueDove Medical Press (Taylor and Francis Group) · 2008
Typearticle
Languageen
FieldMedicine
TopicHospital Admissions and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsPsychologyBusiness
DOInot available

Abstract

fetched live from OpenAlex

James E Paul1, Horia Hangan2, Julius Hajgato31Department of Anesthesia, McMaster University, Hamilton, ON, Canada; 2Faculty of Engineering, The University of Western Ontario, London, ON, Canada; 3Southmedic Inc., Barrie, ON, CanadaBackground: The OxyMask™ is a unique, open-style, oxygen mask that was originally developed in 2005. The original mask was modified, using computational fluid dynamics numerical simulations, with the goal of allowing it to produce a wider range of FiO2. This analysis was used to guide the modification of the mask shell and the location for the oxygen diffuser.Methods: The new OxyMask was attached to 10 healthy subjects and used to deliver escalating levels of oxygen (1.5, 2, 2.5, 3, 5, 10, 15, 20, 25 and 30 LPM) for 90 seconds at each level and the resulting FiO2 was recorded (at the lips) from 5 consecutive measurements at each oxygen flow rate.Results: Mean FiO2 was 25.4% at 1.5 LPM of oxygen, 30.1% at 2 LPM, 36.5% at 2.5 LPM, 41.8% at 3 LPM, 57.6% at 5 LPM, 74.4% at 10 LPM, and 80.1% at 15 LPM. Each FiO2 achieved at these escalating oxygen levels was significantly greater than all the previous levels. The mean FiO2 was 82.8 at 20 LPM, 84.2% at 25 LPM and 84.3% at 30 LPM. All of these values on average were not significantly greater than the FiO2 achieved with 15 LPM. In a few subjects a maximum FiO2 of 90% was reached.Conclusion: The original OxyMask was successfully modified so that the second generation of the mask can provide a wide range of FiO2, from 25% to 90%, while keeping its unique open design.Keywords: oxygen, oxygen masks, oxygen therapy, OxyMask™, OxyArm™, clinical trial, computational fluid dynamics (CFD), equipment design, biomedical engineering

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.703
Threshold uncertainty score0.474

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.276
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueDove Medical Press (Taylor and Francis Group)Same topicHospital Admissions and OutcomesFrench-language works237,207