MétaCan
Menu
Back to cohort
Record W4307092590 · doi:10.1109/tuffc.2022.3216447

Ultrafast Myocardial Principal Strain Ultrasound Elastography During Stress Tests: In Vitro Validation and In Vivo Feasibility

2022· article· en· W4307092590 on OpenAlexafffund
Diya Wang, Boris Chayer, François Destrempes, Jonathan Porée, Marie‐Hélène Roy Cardinal, François Tournoux, Guy Cloutier

Bibliographic record

VenueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2022
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsUniversité de Montréal
FundersNatural Sciences and Engineering Research Council of CanadaFonds de recherche du Québec – Nature et technologiesCanadian Institutes of Health Research
KeywordsSonomicrometryDecorrelationElastographyBiomedical engineeringContractilitySpeckle patternUltrasoundEstimatorStrain rateMaterials scienceMedicineCardiologyMathematicsOpticsPhysicsRadiologyStatisticsHemodynamics

Abstract

fetched live from OpenAlex

Objective myocardial contractility assessment during stress tests aims to improve the diagnosis of myocardial ischemia. Tissue Doppler imaging (TDI) or optical flow (OF) speckle tracking echocardiography (STE) has been used to quantify myocardial contractility at rest. However, this is more challenging during stress tests due to image decorrelation at high heart rates. Moreover, stress tests imply a high frame rate which leads to a limited lateral field of view. Therefore, a large lateral field-of-view robust ultrafast myocardial regularized OF-TDI principal strain estimator has been developed for high-frame-rate echocardiography of coherently compounded transmitted diverging waves. The feasibility and accuracy of the proposed estimator were validated in vitro (using sonomicrometry as the gold standard) and in vivo stress experiments. Compared with OF strain imaging, the proposed estimator improved the accuracy of principal major and minor strains during stress tests, with an average contrast-to-noise ratio improvement of 4.4 ± 2.7 dB (${p}$-value${R}^{{2}}$and biases ± STD between them were 0.96 ± 0.04 (${p}$-value${p}$-value < 0.01) and 0.04 ± 0.06% in the lateral direction, respectively. These results suggest that the proposed estimator could be useful clinically to provide an accurate and quantitative 2-D large lateral field-of-view myocardial strain assessment at high heart rates during stress echocardiography.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.234
Teacher spread0.225 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlSame topicUltrasound Imaging and ElastographyFrench-language works237,207