MétaCan
Menu
Back to cohort
Record W4307280855 · doi:10.24868/10698

The Assessment of Alternative Refrigeration Solutions

2022· preprint· en· W4307280855 on OpenAlexaboutno aff
J Buckingham

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldEngineering
TopicRefrigeration and Air Conditioning Technologies
Canadian institutionsnot available
Fundersnot available
KeywordsRefrigerantChilled waterRefrigerationFlammable liquidMontreal ProtocolEnvironmental scienceAir conditioningFlammabilityWaste managementOzone layerGlobal-warming potentialEnvironmental engineeringOzoneProcess engineeringMeteorologyEngineeringChemistryHeat exchangerGreenhouse gasMechanical engineeringGeography

Abstract

fetched live from OpenAlex

The provision of chilled water is a critical service in any warship as it ensures mission systems can operate reliably within suitably air conditioned spaces. A Chilled Water Plant (CWP) cools circulating clean filtered water through a refrigeration system which passes the heat to sea water (SW). Historically, the refrigerant employed has been damaging to the Earth’s ozone layer but these were outlawed by the UN Montreal Protocol. Since then new refrigerants such as R134a have provided much improved ozone depletion but they have a high Global Warming Potential (GWP) if leaked to the atmosphere. To address the GWP issue, the European directive 2006/40/EC, which went into effect in 2011, required all new cars on sale in Europe to use a refrigerant in its air-conditioning system with a GWP below 150. One group of the new refrigerants to address this required change are called hydrofluoroolefins (HFO) with the R1234yf being a leading candidate for general use with a GWP of 4. However, R1234yf is currently manufactured in limited quantities and so is quite costly. It also has mild flammability with toxic products when combusted. Although it is a close drop-in for R134a, it requires changes to the lubricating oil. Paradoxically, carbon dioxide (CO₂) has long been used as a refrigerant and is often used for cold and freezer displays in shops. It is not flammable and has a GWP of 1, much lower than many alternative refrigerants. However with a critical point of 31°C and 71 bar, a CWP cooled by SW the refrigeration cycle would need to be transcritical, i.e. the use of CO₂ as a supercritical fluid. To obtain a rounded assessment of the benefit of CO₂, versus R134a, the performance of two indicative CWP designs has been analysed. The Coefficient of Performance (COP) and other design and performance issues are identified. The system arrangement and equipment selection issues are addressed, together with a high level consideration of the GWP in-service for different refrigerant leak/loss rates. The ability to drive an absorption chiller plant (ACP) with the heat rejected from the CO₂ CWP is assessed and the energy efficiency and ship cooling benefits are assessed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.957
Threshold uncertainty score0.334

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.299
Teacher spread0.268 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2022
Admission routes1
Has abstractyes

Explore more

Same topicRefrigeration and Air Conditioning TechnologiesFrench-language works237,207