Reliability of visual review of intracranial electroencephalogram in identifying the seizure onset zone: A systematic review and implications for the accuracy of automated methods

2022· review· en· W4307362062 on OpenAlexaff
James Flanary, Samuel R. Daly, Caitlin Bakker, Alexander Herman, Michael C. Park, Robert A. McGovern, Thaddeus S. Walczak, Thomas R. Henry, Théoden I. Netoff, David Darrow

Bibliographic record

VenueEpilepsia · 2022
Typereview
Languageen
FieldMedicine
TopicEpilepsy research and treatment
Canadian institutionsUniversity of Regina
Fundersnot available
KeywordsReliability (semiconductor)KappaMeta-analysisCochrane LibraryComputer scienceEpilepsy surgeryEpilepsySystematic reviewMEDLINEElectroencephalographyArtificial intelligenceVisual inspectionMedical physicsMedicineMachine learningPsychiatryPathology

Abstract

fetched live from OpenAlex

Visual review of intracranial electroencephalography (iEEG) is often an essential component for defining the zone of resection for epilepsy surgery. Unsupervised approaches using machine and deep learning are being employed to identify seizure onset zones (SOZs). This prompts a more comprehensive understanding of the reliability of visual review as a reference standard. We sought to summarize existing evidence on the reliability of visual review of iEEG in defining the SOZ for patients undergoing surgical workup and understand its implications for algorithm accuracy for SOZ prediction. We performed a systematic literature review on the reliability of determining the SOZ by visual inspection of iEEG in accordance with best practices. Searches included MEDLINE, Embase, Cochrane Library, and Web of Science on May 8, 2022. We included studies with a quantitative reliability assessment within or between observers. Risk of bias assessment was performed with QUADAS-2. A model was developed to estimate the effect of Cohen kappa on the maximum possible accuracy for any algorithm detecting the SOZ. Two thousand three hundred thirty-eight articles were identified and evaluated, of which one met inclusion criteria. This study assessed reliability between two reviewers for 10 patients with temporal lobe epilepsy and found a kappa of .80. These limited data were used to model the maximum accuracy of automated methods. For a hypothetical algorithm that is 100% accurate to the ground truth, the maximum accuracy modeled with a Cohen kappa of .8 ranged from .60 to .85 (F-2). The reliability of reviewing iEEG to localize the SOZ has been evaluated only in a small sample of patients with methodologic limitations. The ability of any algorithm to estimate the SOZ is notably limited by the reliability of iEEG interpretation. We acknowledge practical limitations of rigorous reliability analysis, and we propose design characteristics and study questions to further investigate reliability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.213
metaresearch head score (Gemma)0.612
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.213
Threshold uncertainty score0.970

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.2130.612
Meta-epidemiology (narrow)0.0020.002
Meta-epidemiology (broad)0.0100.013
Bibliometrics0.0260.020
Science and technology studies0.0010.004
Scholarly communication0.0060.007
Open science0.0040.004
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.070
GPT teacher head0.485
Teacher spread0.415 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueEpilepsiaSame topicEpilepsy research and treatmentFrench-language works237,207