MétaCan
Menu
Back to cohort
Record W4308060951 · doi:10.1002/mp.16079

Experimental optimization of single‐exposure dual‐energy angiography with photon‐counting x‐ray detectors

2022· article· en· W4308060951 on OpenAlexaff
Sarah Aubert, Jesse Tanguay

Bibliographic record

VenueMedical Physics · 2022
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsToronto Metropolitan University
Fundersnot available
KeywordsOpticsImaging phantomMaterials scienceKermaDetectorX-ray detectorPhoton energyPhoton countingEnergy (signal processing)Figure of meritPhysicsPhotonNuclear medicineDosimetryMedicine

Abstract

fetched live from OpenAlex

Abstract Background Photon‐counting x‐ray detectors may enable single‐exposure dual‐energy (DE) x‐ray angiography. Purpose The purpose of this paper is to experimentally optimize the energy thresholds and tube voltage for single‐exposure DE x‐ray angiography. Methods We optimized single‐exposure DE x‐ray angiography using the iodine signal‐difference‐to‐noise ratio (SDNR) per root patient air kerma (κ) as a figure of merit. We measured the iodine SDNR by imaging an iodine stepwedge immersed in a water tank with a depth of 30 cm in the direction of x‐ray propagation. The stepwedge was imaged using tube voltages ranging from 90 to 150 kV and a cadmium telluride (CdTe) x‐ray detector with two energy bins and analog charge summing for charge sharing suppression. The energy threshold that separates the two energy bins was varied from approximately 35 keV to approximately 75% of the maximum energy of the x‐ray beam. Curve fitting was used to determine the threshold that maximized . The effect of scatter was determined from measurements of the scatter‐to‐primary ratios (SPRs) of the low‐energy and high‐energy images and a semi‐empirical model of the relationship between SDNR and SPR. Using the optimal parameters, we imaged a phantom with vessel‐simulating structures and background clutter. Results The optimal energy thresholds increased monotonically from ∼50 to ∼85 keV over the range of tube voltages considered. For tube voltages greater than 90 kV, the optimal energy thresholds consistently allocated approximately two thirds of all detected primary photons to the low energy bin; this ratio was preserved without scatter. Consistent with prior modeling studies, increased monotonically with tube voltage from 90 to 150 kV; at 150 kV was approximately 38% higher than that at 90 kV for an iodine area density of ∼50 mg/cm 2 . Scatter reduced SDNR by approximately 25% for SPRs of ∼1 and 0.4 in low‐energy and high‐energy images, respectively. Conclusions Achieving optimal image quality in single‐exposure DE angiography with photon‐counting x‐ray detectors will require high tube voltages (i.e., >130 kV) and, for thick patients, energy thresholds that allocate approximately two thirds of all primary photons to the low‐energy image. Future work will compare the image quality of singe‐exposure photon‐counting and kV‐switching approaches to DE x‐ray angiography.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.741
Threshold uncertainty score0.518

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.189
Teacher spread0.184 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced X-ray and CT ImagingFrench-language works237,207