MétaCan
Menu
Back to cohort
Record W4308294031 · doi:10.1007/s00167-022-07216-8

Ten‐year follow‐up of a total knee prosthesis combining multi‐radius, ultra‐congruency, posterior‐stabilization and mobile‐bearing insert shows long‐lasting clinically relevant improvements in pain, stiffness, function and stability

2022· article· en· W4308294031 on OpenAlexaboutno aff
Killian Cosendey, Antoine Eudier, Nicole Fleury, L.C. Pereira, Julien Favre, Brigitte M. Jolles

Bibliographic record

VenueKnee Surgery Sports Traumatology Arthroscopy · 2022
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsnot available
FundersUniversité de Lausanne
KeywordsMedicineProsthesisOsteoarthritisWOMACArthroplastyWilcoxon signed-rank testPhysical therapySurgeryMann–Whitney U test

Abstract

fetched live from OpenAlex

Abstract Purpose There is a paucity of data available on total knee prostheses combining dual‐radius, ultra‐congruency, posterior‐stabilization and mobile‐bearing insert. This prospective cohort study aimed to assess the clinical evolution of the FIRST® prosthesis (Symbios Orthopédie, Yverdon, CH), the earliest prosthesis with this particular design. It was hypothesized that the primary outcomes, evaluating pain, stiffness, function and stability, would improve following arthroplasty and remain improved during the follow‐up period of 10 years. Methods All patients programmed for a total knee arthroplasty using a FIRST® prosthesis at our university hospital between 2006 and 2008 were invited to participate. Study knees were evaluated pre‐operatively as well as one, five and ten years post‐operatively. Patients filled out questionnaires at each evaluation point and had a radiographic assessment at the five‐year and ten‐year follow‐ups. Primary outcomes were the total, pain, stiffness and function measures of the Western Ontario and McMaster Universities Osteoarthritis questionnaire (WOMAC) and the knee and function measures of the Knee Society Score (KSS). Friedman and Wilcoxon’s rank‐sum tests were used to compare measures across time points. Results Hundred and twenty four prostheses were included (baseline demographics: 69.9 ± 8.3 years old, 28.1 ± 4.3 kg/m2, 54% male) and 68 could be followed during ten years. Five prostheses underwent a revision. All other prostheses lost at follow‐up were lost for reasons unrelated to the prosthesis. All primary measures reported statistically and clinically significant improvements between baseline and the three follow‐up evaluations. Statistically significant improvements at the three follow‐up evaluations were also observed for most secondary measures. There was no implant loosening. At ten‐year follow‐up, radiolucent lines were observed in 2.9% femoral implants and 1.5% tibial implants. Conclusion The positive results observed in all domains of assessment and the small revision rate demonstrated an effective functioning of the FIRST® prosthesis during the ten‐year follow‐up period. The results, globally similar to those previously published for other prosthesis designs, encourage the development of assistive methods to select the most appropriate designs on an individual basis. Level of evidence IV, prospective cohort study.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.256
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueKnee Surgery Sports Traumatology ArthroscopySame topicTotal Knee Arthroplasty OutcomesFrench-language works237,207