MétaCan
Menu
Back to cohort
Record W4308368577 · doi:10.1002/dta.3398

Electrophoretic detection of black market myostatin propeptide

2022· article· en· W4308368577 on OpenAlexfundno aff
Christian Reichel, Günter Gmeiner, Mario Thevis

Bibliographic record

VenueDrug Testing and Analysis · 2022
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicMuscle Physiology and Disorders
Canadian institutionsnot available
FundersWorld Anti-Doping Agency
KeywordsProtein precursorMyostatinPolyclonal antibodiesDetection limitBiotinylationChemistryMolecular biologyMonoclonal antibodyBlotFollistatinAntibodyChromatographyBiologyBiochemistryGeneImmunologyEndocrinology

Abstract

fetched live from OpenAlex

Myostatin propeptide is prohibited according to chapter S4 of the "WADA 2022 List of Prohibited Substances and Methods." So far, no approved myostatin-propeptide pharmaceuticals are available. Nevertheless, myostatin-propeptides can be bought on the black market for "research purposes." A study on black market myostatin propeptide products is presented as well as electrophoretic detection methods for serum and urine. Out of the 12 tested products, only nine actually contained the protein. Separation by SDS-PAGE revealed that the nine products were relatively impure and that the main compound had a much higher mass (approximately 54-55 kDa) than expected (approximately 33 kDa). Further analyses by mass spectrometry showed that the elevated molecular mass was due to the presence of a full length GST-tag on the propeptide. The developed detection method for serum is based on immunoprecipitation (IP) followed by SDS-PAGE and Western blotting. In total, three anti-myostatin propeptide antibodies were tested. All of them were well suited for either IP or immunoblotting. The final protocol applies a biotinylated polyclonal antibody, streptavidin-coated magnetic beads, and a monoclonal detection antibody. For a sample volume of 500 μL serum, the detection limit of the method is approximately 2.5 ng/mL. The urine method applies a commercial ELISA for IP and performs with a limit of detection (LOD) of approximately 0.4 ng/mL. Furthermore, practically all currently available myostatin propeptide standards were also investigated. Due to the significant molecular mass difference of the black market products, an unambiguous differentiation from endogenous myostatin propeptide is possible.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0020.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0050.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.212
Teacher spread0.206 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueDrug Testing and AnalysisSame topicMuscle Physiology and DisordersFrench-language works237,207