Short-Term Fit Assessment of a Novel Daily Disposable, Toric, Silicone Hydrogel Contact Lens
Bibliographic record
Abstract
Purpose: The development of new contact lens materials and designs are necessary to minimise patient dropout. A lens material with water surface technology was recently developed to incorporate toric design. The on-eye stability of a toric contact lens is critical to a successful toric lens fitting. In an effort to establish if the new daily disposable verofilcon A toric silicone hydrogel lens provides fast stability for ease of fit, this study assessed the initial and short-term on-eye stability of this new lens. Patients and Methods: Habitual full-time wearers of soft contact lenses, aged 18 or over, were enrolled and fit with the verofilcon A toric lens. Study endpoints included lens settling time, axis orientation at specific time-points within 10 minutes after insertion, lens oscillation with blink, lens movement and centration, and scribe mark visibility. Results: Thirty-nine subjects completed the study; 67% were female and mean age was 34.1 ± 10.8 years (range 18 to 61). The majority of verofilcon A toric lenses (98.7%) settled on average within 60 seconds. Average lens orientation was 3° from six o'clock position within two minutes of insertion. The lenses showed minimal oscillation with blink; 98.7% of the eyes demonstrated ≤5° oscillation with blink. All lenses showed optimal/acceptable lens movement and centration and the scribe mark was reported as easily visible in 96% of eyes. Practitioners reported a 99% first lens fit success rate. Conclusion: The novel verofilcon A toric lens was highly successful with the first lens, had excellent on-eye stability and good fit characteristics. These qualities make this new lens a good option for lens wearers. Furthermore, it fulfills the needs of practitioners who want a toric lens that is easy and predictable to fit.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".