MétaCan
Menu
Back to cohort
Record W4309705231 · doi:10.22323/1.414.0846

A 16-sensor prototype for brachytherapy in vivo dosimetry characterization

2022· article· en· W4309705231 on OpenAlexfundno aff
A. Giaz, Marco Galoppo, Nikolay Ampilogov, S. Cometti, Sergio Esteve, Jennifer Hanly, Orla A. Houlihan, Wern Kam, Micheal Martyn, Owen McLaughlin, Romualdo SANTORO, Gerardine Workman, Peter Woulfe, M. Caccia, Sinéad O’Keeffe

Bibliographic record

VenueProceedings of 41st International Conference on High Energy physics — PoS(ICHEP2022) · 2022
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsnot available
FundersQueen's University
KeywordsDosimeterDosimetryDetectorBrachytherapyReproducibilitySilicon photomultiplierMaterials scienceOptical fiberComputer scienceMedical physicsBiomedical engineeringNuclear medicineEngineeringPhysicsRadiation therapyMedicineTelecommunications

Abstract

fetched live from OpenAlex

The ORIGIN project (Optical Fiber Dose Imaging for Adaptive Brachytherapy) targets the production and qualification of a real-time radiation dose imaging and source localization system for both Low Dose Rate and High Dose Rate brachytherapy treatments. This goal will be achieved through a 16-fibre sensor system. Each fibre tip has been engineered to house a small volume of scintillating material to allow for measurements of the delivered dose. The instrument is based on Silicon Photomultipliers detectors, with a solution fully qualified on a single fibre prototype and currently being scaled up through the use of the CITIROC1A ASIC by WEEROC, embedded in the FERS-DT5202 scalable platform designed by CAEN S.p.A. The key features for a system such as ORIGIN, which aims to perform dose measurements in a clinical environment, are fibre response uniformity, system stability, high sensitivity, and perfect reproducibility. The commissioning of the 16-channel dosimeter system in laboratory conditions, with an X-ray cabinet, demonstrated reproducibility of measurements with deviations below 1% after the equalization procedure of the 16 sensors. Finally, the system performance, evaluated in clinical conditions (High Dose Rate centre, Belfast Hospital), allowed for valuable insight into the possible systematics which are present in the current system while simultaneously corroborating the validity of the equalization procedure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.009
Threshold uncertainty score0.030

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0090.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.279
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of 41st International Conference on High Energy physics — PoS(ICHEP2022)Same topicAdvanced Radiotherapy TechniquesFrench-language works237,207