MétaCan
Menu
Back to cohort
Record W4310601137 · doi:10.1055/s-0042-1758818

Laboratory Testing for Heparin-Induced Thrombocytopenia and Vaccine-Induced Immune Thrombotic Thrombocytopenia Antibodies: A Narrative Review

2022· review· en· W4310601137 on OpenAlexaff
Theodore E. Warkentin, Andreas Greinacher

Bibliographic record

VenueSeminars in Thrombosis and Hemostasis · 2022
Typereview
Languageen
FieldMedicine
TopicHeparin-Induced Thrombocytopenia and Thrombosis
Canadian institutionsMcMaster UniversityHamilton Regional Laboratory Medicine ProgramHamilton Health SciencesHamilton General Hospital
Fundersnot available
KeywordsPlatelet factor 4Heparin-induced thrombocytopeniaHeparinAntibodyImmunologyPlatelet activationPlateletImmune systemAntigenMedicineImmune complexInternal medicine

Abstract

fetched live from OpenAlex

Abstract Heparin-induced thrombocytopenia (HIT) and vaccine-induced immune thrombotic thrombocytopenia (VITT) are highly prothrombotic (thrombosis frequency ≥50%). Both are caused by platelet-activating anti-platelet factor 4 (PF4) antibodies, forming PF4/IgG-containing immune complexes that engage platelet FcγIIa receptors, producing strong platelet activation. In HIT, heparin crosslinks several PF4 molecules, whereas in VITT, anti-PF4 antibodies alone crosslink PF4. Sufficient levels of circulating anti-PF4 antibodies are needed to create the pathogenic immune complexes on platelet surfaces; this explains why certain serum (plasma)-based assays are highly sensitive for detecting HIT/VITT antibodies. Accordingly, HIT and VITT are “clinical-pathological” disorders, that is, positive testing for such antibodies—together with a compatible clinical picture—is integral for diagnosis. Heparin (low concentrations) enhances HIT antibody-induced platelet activation, but platelet activation by VITT sera is usually inhibited by heparin. For both HIT and VITT, high sensitivity (>99% and >95%, respectively) characterizes PF4-dependent enzyme immunoassays (EIAs) and PF4-enhanced platelet activation assays; in contrast, certain rapid immunoassays have high sensitivity for HIT (>90-97%) but poor sensitivity (<25%) for VITT. HIT and VITT antibodies are directed at distinct sites on PF4: solid-phase EIAs and platelet activation assays are indifferent to these distinct antigen targets, but rapid immunoassays are not. We discuss a conceptual model where PF4 is viewed as a “globe,” with the heparin-binding site the “equator”; in this model, HIT antibodies are primarily directed at antigen site(s) at the north and south “poles” of PF4 (formed when PF4 binds to heparin), whereas VITT antibodies recognize sites on the equator.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.009
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.007
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.009
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0070.005
Science and technology studies0.0000.001
Scholarly communication0.0020.002
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.146
GPT teacher head0.406
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations46
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueSeminars in Thrombosis and HemostasisSame topicHeparin-Induced Thrombocytopenia and ThrombosisFrench-language works237,207