Validation of laser Doppler flowmetry for the continuous measurement of women's genital response

2022· article· en· W4310938663 on OpenAlexafffund
Katrina N. Bouchard, Caroline F. Pukall

Bibliographic record

VenuePsychophysiology · 2022
Typearticle
Languageen
FieldMedicine
TopicThermoregulation and physiological responses
Canadian institutionsQueen's University
FundersCanadian Institutes of Health Research
KeywordsLaser Doppler velocimetrySex organSexual arousalPsychologyBlood flowMedicineInternal medicineDevelopmental psychologySexual behaviorBiology

Abstract

fetched live from OpenAlex

Laser Doppler imaging is a valid method of assessing genital response, detecting increases in genital blood flow to sexual, but not nonsexual stimuli. Although laser Doppler imaging provides a direct measure of genital blood flow, its discrete perfusion images provide a discontinuous assessment of genital response, limiting some study designs. The aims of this study were to investigate the measurement properties of laser Doppler flowmetry, a direct and continuous measure of blood flow, as well as examine the time course of genital response using flowmetry. A sample of 45 cisgender women attended two experimental sessions wherein they viewed sexual and nonsexual stimuli (e.g., neutral, anxiety, humor) while their genital responses were assessed using laser Doppler flowmetry. As expected, laser Doppler flowmetry was a valid measure of genital response-detecting increases in genital blood flow elicited by the sexual stimuli only-and was sensitive to varying degrees of genital response elicited by low, moderate, and high-intensity sexual stimuli. The measure also exhibited convergent validity with genital response assessed via laser Doppler imaging, test-retest reliability across testing sessions, and internal consistency as well as high sexual concordance with self-reported sexual arousal. Descriptive analyses showed that genital blood flow assessed using laser Doppler flowmetry was highly responsive, with initial, peak, and return to baseline responses occurring within timeframes appropriate for repeated measurement within a single session. Laser Doppler flowmetry is a valid, reliable, and sensitive measure of women's genital response that can be usefully applied in sexual psychophysiology research.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.657
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.302
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2022
Admission routes2
Has abstractyes

Explore more

Same venuePsychophysiologySame topicThermoregulation and physiological responsesFrench-language works237,207