Platelet RNA sequencing for cancer screening in patients with unprovoked venous thromboembolism: a prospective cohort study
Bibliographic record
Abstract
BACKGROUND: Platelet RNA sequencing has been shown to accurately detect cancer in previous studies. OBJECTIVES: To compare the diagnostic accuracy of platelet RNA sequencing with standard-of-care limited cancer screening in patients with unprovoked venous thromboembolism (VTE). METHODS: Patients aged ≥40 years with unprovoked VTE were recruited at 13 centers and followed for 12 months for cancer. Participants underwent standard-of-care limited cancer screening, and platelet RNA sequencing analysis was performed centrally at study end for cases and selected controls. Sensitivity and specificity were calculated, using the predefined primary positivity threshold of 0.54 for platelet RNA sequencing aiming at 86% test sensitivity, and an additional predefined threshold of 0.89 aiming at 99% test specificity. RESULTS: A total of 476 participants were enrolled, of whom 25 (5.3%) were diagnosed with cancer during 12-month follow-up. For each cancer patient, 3 cancer-free patients were randomly selected for the analysis. The sensitivity of limited screening was 72% (95% CI, 52-86) at a specificity of 91% (95% CI, 82-95). The area under the receiver operator characteristic for platelet RNA sequencing was 0.54 (95% CI, 0.41-0.66). At the primary positivity threshold, all patients had a positive test, for a sensitivity estimated at 100% (95% CI, 87-99) and a specificity of 8% (95% CI, 3.7-16.4). At the secondary threshold, sensitivity was 68% (95% CI, 48-83; p value compared with limited screening 0.71) at a specificity of 36% (95% CI, 26-47). CONCLUSION: Platelet RNA sequencing had poor diagnostic accuracy for detecting occult cancer in patients with unprovoked VTE with the current algorithm.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.003 | 0.007 |
| Meta-epidemiology (narrow) | 0.000 | 0.001 |
| Meta-epidemiology (broad) | 0.000 | 0.001 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".