MétaCan
Menu
Back to cohort
Record W4317831315 · doi:10.1038/s41598-023-27376-y

Feasibility of a multigroup Boltzmann–Fokker–Planck solution for electron beam dose calculations

2023· article· en· W4317831315 on OpenAlexafffund
Ahmed Naceur, Alain Hébert, Paul Romano, Benoit Forget, Cornelia Chilian, Jean‐François Carrier

Bibliographic record

VenueScientific Reports · 2023
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsUniversité de MontréalCentre Hospitalier de l’Université de MontréalPolytechnique Montréal
FundersCanada First Research Excellence FundJewish General HospitalNatural Sciences and Engineering Research Council of CanadaMcGill University
KeywordsVoxelPhysicsBoltzmann equationMonte Carlo methodBenchmark (surveying)Imaging phantomBoltzmann constantBeam (structure)Linear particle acceleratorComputational physicsComputer scienceNuclear medicineStatistical physicsMathematicsOpticsStatisticsQuantum mechanicsArtificial intelligenceMedicine

Abstract

fetched live from OpenAlex

Legacy nuclear-reactor Boltzmann solvers start clinical deployment as an alternative to Monte Carlo (MC) codes and Fermi-Eyges semiemprical models in radiation oncology treatment planning. Today's certified clinical solvers are limited to photon beams. In this paper, ELECTR, a state-of-the-art multigroup electron cross sections generation module in NJOY is presented and validated against Lockwood's calorimetric measurements, EGS-nrc and GEANT-4 for 1-20 MeV unidirectional electron beams. The nuclear-reactor DRAGON-5 solver is upgraded to access the library and solve the Boltzmann-Fokker-Planck (BFP) equation. A variety of heterogeneous radiotherapy and radiosurgery phantom configurations were used for validation purpose. Case studies include a thorax benchmark, that of a typical breast Intra-Operative Radiotherapy and a high-heterogeneity patient-like benchmark. For all beams, [Formula: see text] of the water voxels satisfied the American Association of Physicists in Medicine accuracy criterion for a BFP-MC dose error below [Formula: see text]. At least, [Formula: see text] of adipose, muscle, bone, lung, tumor and breast voxels satisfied the [Formula: see text] criterion. The average BFP-MC relative error was about [Formula: see text] for all voxels, beams and materials combined. By irradiating homogeneous slabs from [Formula: see text] (hydrogen) to [Formula: see text] (einsteinium), we reported performance and defects of the CEPXS mode [US. Sandia National Lab., SAND-89-1685] in ELECTR for the entire periodic table. For all Lockwood's benchmarks, NJOY-DRAGON dose predictions are within the experimental data precision for [Formula: see text] of voxels.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.009
Threshold uncertainty score0.030

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0090.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.043
GPT teacher head0.347
Teacher spread0.303 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueScientific ReportsSame topicRadiation Therapy and DosimetryFrench-language works237,207