MétaCan
Menu
Back to cohort
Record W4318754014 · doi:10.1097/pxr.0000000000000208

Design and evaluation of a hip prosthesis simulator: A technical note

2023· article· en· W4318754014 on OpenAlexaff
Amir Fanous, Michael Botros, Hossein Gholizadeh, Natalie Baddour, Edward D. Lemaire

Bibliographic record

VenueProsthetics and Orthotics International · 2023
Typearticle
Languageen
FieldEngineering
TopicProsthetics and Rehabilitation Robotics
Canadian institutionsOttawa HospitalUniversity of Ottawa
Fundersnot available
KeywordsHemipelvectomyProsthesisPelvisAdapter (computing)AmputationComputer scienceMedicineSimulationPhysical medicine and rehabilitationSurgeryComputer hardware

Abstract

fetched live from OpenAlex

People with a limb loss at the level of the hip or pelvis have the most difficulty returning to walking compared with those with a lower amputation. This is because their prosthesis must replace the hip, knee, and ankle joints. An adjustable hip-disarticulation/hemipelvectomy prosthesis simulator that allows able-bodied individuals to wear and assess a prosthesis can help researchers and manufacturers when designing new prosthetic components (ie, hip joints). SolidWorks computer-aided design software was used to design and simulate an adapter that can connect prosthetic components to an off-the-shelf hip abduction orthosis. The adapter was made of 1020 stainless steel and aluminium 6061-T3 with a yield strength of 276 MPa. To confirm that this adapter is strong and safe for ambulation, mechanical testing was performed using an INSTRON machine. The maximum loads generated in any activity were chosen according to the International Organization for Standardization 15032:2000 standard for hip disarticulation external prostheses. The designed adapter allowed frontal, lateral, or distal mounting of different prosthetic hip joints. Mechanical testing confirmed that the new adapter can withstand forces and moments experienced during ambulation. The hip disarticulation/hemipelvectomy prosthesis simulator is easy to use and adjustable based on each person's height and pelvic width. Furthermore, this simulator would assist rehabilitation practitioners in experiencing the use of hip-level prostheses and give them a better understanding of people using such technologies. The next step in this project is to evaluate able-bodied participant gait while using this hip simulator prosthesis with different hip joints.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.101
Threshold uncertainty score0.453

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.292
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueProsthetics and Orthotics InternationalSame topicProsthetics and Rehabilitation RoboticsFrench-language works237,207