MétaCan
Menu
Back to cohort

Implantable cardiac defibrillators in octogenarians

2023· article· en· W4323294517 on OpenAlexaff
Maarten Pauwelyn, Sebastian Ingelaere, Ruben Hoffmann, Johan Vijgen, Georges H. Mairesse, Ivan Blankoff, Yves Vandekerckhove, Jean‐Benoît le Polain de Waroux, Bert Vandenberk, Rik Willems

Bibliographic record

VenueJournal of Geriatric Cardiology · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsLibin Cardiovascular Institute of AlbertaUniversity of Calgary
Fundersnot available
KeywordsMedicineEjection fractionHazard ratioProportional hazards modelInternal medicineAtrial fibrillationImplantable cardioverter-defibrillatorCardiologyPopulationHeart failureConfidence interval

Abstract

fetched live from OpenAlex

<sec><strong>OBJECTIVE</strong> Implantable cardiac defibrillators (ICD) implantation in the very elderly remains controversial. We aimed to describe the experience and outcome of patients over 80 years old implanted with an ICD in Belgium. </sec><sec><strong>METHODS</strong> Data were extracted from the national QERMID-ICD registry. All implantations performed in octogenarians between February 2010 and March 2019 were analysed. Data on baseline patient characteristics, type of prevention, device configuration and all-cause mortality were available. To determine predictors of mortality, multivariable Cox proportional hazard regression modelling was performed. </sec><sec><strong>RESULTS</strong> Nationwide, 704 primo ICD implantations were performed in octogenarians (median age 82, IQR 81-83 years; 83% male and 45% secondary prevention). During a mean follow-up of 3.1 ± 2.3 years, 249 (35%) patients died, of which 76 (11%) within the first year after implantation. In multivariable Cox regression analysis age (HR = 1.15, <i>P</i> = 0.004), oncological history (HR = 2.43, <i>P</i> = 0.027) and secondary prevention (HR = 2.23, <i>P</i> = 0.001) were independently associated with 1-year mortality. A better preserved left ventricular ejection fraction (LVEF) was associated with a better outcome (HR = 0.97, <i>P</i> = 0.002). Regarding overall mortality multivariable analysis withheld age, history of atrial fibrillation, centre volume and oncological history as significant predictors. Higher LVEF was again protective (HR = 0.99, <i>P</i> = 0.008). </sec><sec><strong>CONCLUSIONS</strong> Primary ICD implantation in octogenarians is not often performed in Belgium. Among this population, 11% died within the first year after ICD implantation. Advanced age, oncological history, secondary prevention and a lower LVEF were associated with an increased one-year mortality. Age, low LVEF, atrial fibrillation, centre volume and oncological history were indicative of higher overall mortality. </sec>

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.092
Threshold uncertainty score0.435

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.294
Teacher spread0.274 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Geriatric CardiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207