MétaCan
Menu
Back to cohort
Record W4323540085 · doi:10.1371/journal.pgph.0001354

Feasibility and usability of a very low-cost bubble continuous positive airway pressure device including oxygen blenders in a Ugandan level two newborn unit

2023· article· en· W4323540085 on OpenAlexfundno aff
Anna B. Hedstrom, James Nyonyintono, Eugene Saxon, Heidi Nakamura, Hilda Namakula, Beatrice Niyonshaba, Josephine Nakakande, Noelle Simpson, Madeline Vaughan, Alec Wollen, Paul Mubiri, Peter Waiswa, Patricia S. Coffey, Maneesh Batra

Bibliographic record

VenuePLOS Global Public Health · 2023
Typearticle
Languageen
FieldMedicine
TopicNeonatal Respiratory Health Research
Canadian institutionsnot available
FundersDirektoratet for UtviklingssamarbeidGrand Challenges CanadaKorea International Cooperation AgencyDepartment for International DevelopmentUniversity of WashingtonBill and Melinda Gates FoundationUnited States Agency for International Development
KeywordsMedicineContinuous positive airway pressureUsabilityPediatricsEmergency medicineAnesthesiaComputer science

Abstract

fetched live from OpenAlex

BACKGROUND: Preterm birth and resulting respiratory failure is a leading cause of newborn death- the majority of which occur in resource-constrained settings and could be prevented with bubble continuous positive airway pressure (bCPAP). Commercialized devices are expensive, however, and sites commonly use improvised devices utilizing 100% oxygen which can cause blindness. To address this, PATH and a multidisciplinary team developed a very low-cost bCPAP device including fixed-ratio oxygen blenders. OBJECTIVE: We assessed feasibility of use of the device on neonatal patients as well as the usability and acceptability of the device by healthcare workers. This study did not evaluate device effectiveness. METHODS: The study took place in a Ugandan level two unit. Neonates with respiratory failure were treated with the bCPAP device. Prospective data were collected through observation as well as likert-style scales and interviews with healthcare workers. Data were analyzed using frequencies, means and standard deviation and interviews via a descriptive coding method. Retrospectively registered via ClinicalTrials.gov number NCT05462509. RESULTS: Fourteen neonates were treated with the bCPAP device in October-December 2021. Patients were born onsite (57%), with median weight of 1.3 kg (IQR 1-1.8). Median treatment length was 2.5 days (IQR 2-6). bCPAP was stopped due to: improvement (83%) and death (17%). All patients experienced episodes of saturations >95%. Median time for device set up: 15 minutes (IQR 12-18) and changing the blender: 15 seconds (IQR 12-27). After initial device use, 9 out of 9 nurses report the set-up as well as blender use was "easy" and their overall satisfaction with the device was 8.5/10 (IQR 6.5-9.5). Interview themes included the appreciation for the ability to administer less than 100% oxygen, desire to continue use of the device, and a desire for additional blenders. CONCLUSIONS: In facilities otherwise using 100% oxygen, use of the bCPAP device including oxygen blenders is feasible and acceptable to healthcare workers. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier NCT05462509.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.005
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.107
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.003
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.240
GPT teacher head0.433
Teacher spread0.193 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2023
Admission routes1
Has abstractyes

Explore more

Same venuePLOS Global Public HealthSame topicNeonatal Respiratory Health ResearchFrench-language works237,207