Measurement Uncertainty in Clinical Validation Studies of Sensors
Bibliographic record
Abstract
Accurate clinical sensors and devices are essential to support optimal medical decision-making, and accuracy can be demonstrated through the conduct of clinical validation studies using validated reference sensors and/or devices for comparison. Typically unmeasurable, the true reference value can be substituted with an accepted physiological measurement with an associated uncertainty. We describe a basic model of measurement uncertainty that specifies the factors that may degrade the accuracy of an observed measurement value from a sensor, and we detail validation study design strategies that may be used to quantify and minimize these uncertainties. In addition, we describe a model that extends the observed measurement uncertainty to the resultant clinical decision and the factors that may impact the uncertainty of this decision. Clinical validation studies should be designed to estimate and minimize uncertainty that is unrelated to the sensor accuracy. The contribution of measurement observation uncertainty to clinical decision-making should be minimized but also acknowledged and incorporated into the clinical decision-making process.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.301 | 0.590 |
| Meta-epidemiology (narrow) | 0.002 | 0.001 |
| Meta-epidemiology (broad) | 0.003 | 0.003 |
| Bibliometrics | 0.003 | 0.002 |
| Science and technology studies | 0.002 | 0.007 |
| Scholarly communication | 0.006 | 0.006 |
| Open science | 0.004 | 0.005 |
| Research integrity | 0.005 | 0.004 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; the direct Gemma label and the distilled Codex classifier agree on what is shown here.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".