OBJECTIVES: Analysis of the in vitro efficacy of non-surgical and surgical dental implant surface decontamination with or without suprastructure. MATERIALS AND METHODS: Three hundred and sixty implants were dipped in indelible red and distributed to 30°, 60°, or 90° angulated bone defect models. One hundred and twenty implants were used for each bone defect, 40 of which were assigned to a decontamination method (CUR: curette; SOSC: soundscaler; APA: air powder abrasion). Of these, 20 were subjected to a simulated non-surgical (NST) or surgical treatment (ST), with/without mucosa mask, of which 10 were carried out with (S+) or without (S-) suprastructure. Uncleaned implant surface was assessed by both-sided implant surface photography. Surface morphology changes were analyzed using scanning electron microscopy (SEM). RESULTS: Cleaning efficacy was significantly better within NST if the suprastructure was removed (p < 0.001). No significant difference was found within ST (p = 0.304). Overall, cleaning efficacy in the order APA > SOSC>CUR decreased significantly (p < 0.0001) for both S+ and S- in NST as well as ST. Separated by NST/ST, S+/S-, defect angulation and decontamination method, only isolated significant differences in cleaning efficacy were present. Linear regression analysis revealed significant associations of remnants with the treatment approach, decontamination method, and defect angle (p < 0.0001). SEM micrographs showed serious surface damage after use of CUR and SOSC. CONCLUSIONS: Suprastructure removal is an additional option to improve cleaning efficacy of non-surgical implant surface decontamination in this in vitro model.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.120
GPT teacher head0.513
Teacher spread0.393 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→