MétaCan
Menu
Back to cohort
Record W4327623588 · doi:10.3390/app13063785

Temperature- and Frequency-Dependent Nonlinearities of an Integrated Hydro-Pneumatic Suspension with Mixed Gas-Oil Emulsion Flow

2023· article· en· W4327623588 on OpenAlexafffund
Yuming Yin, Zhenting Wang, Zhijun Fu, Jianshan Lu, Subhash Rakheja

Bibliographic record

VenueApplied Sciences · 2023
Typearticle
Languageen
FieldEngineering
TopicHydraulic and Pneumatic Systems
Canadian institutionsConcordia University
FundersUniversity of Science and Technology BeijingConcordia UniversityBasic Public Welfare Research Program of Zhejiang ProvinceNational Natural Science Foundation of China
KeywordsMaterials scienceSuspension (topology)EmulsionPolytropic processMechanicsVolume fractionStiffnessComposite materialThermodynamicsChemistryPhysics

Abstract

fetched live from OpenAlex

Hydro-pneumatic suspension (HPS) systems are increasingly being implemented in commercial vehicles and various industrial equipment, which is mainly attributed to the integration of adaptable nonlinear pneumatic stiffness and hydraulic damping properties. The integrated HPS design with a shared gas-oil chamber, however, leads to gas-oil emulsion flow within the suspension chambers, which intricately affects the internal and external properties of the HPS, especially under variations in temperature and excitation frequency. This study experimentally and analytically investigated the temperature- and frequency-dependent properties of the hydro-pneumatic suspension with the gas-oil emulsion. Laboratory experiments were performed under three different near-constant temperatures (30, 40, and 50 °C) in the 0.5–8 Hz frequency range. An analytical model of the HPS was formulated considering the effects of temperature on internal fluid properties, gas-oil emulsion flow between the coupled chambers, the dynamic seal friction, and polytropic change in the gas state. The internal parameters, including the gas volume fraction, the discharge coefficient of the emulsion, and the dynamic friction components, as well as the external stiffness and damping characteristics, were determined. The relationships between these properties and the system temperature, velocity, and excitation frequency were further investigated. The simulated responses obtained under different excitations showed reasonably good agreement with the experimental results of the HPS. The results suggested that increased temperature yielded greater equivalent stiffness and comparable damping properties of the system. The gas volume fraction, discharge coefficient, and magnitude of seal friction generally tended to increase with increasing temperature. Increased excitation frequency led to greater hysteresis in hydraulic damping force and seal friction, and reduced seal friction magnitude and Stribeck effect.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.213
Teacher spread0.201 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueApplied SciencesSame topicHydraulic and Pneumatic SystemsFrench-language works237,207