MétaCan
Menu
Back to cohort
Record W4360804722 · doi:10.1089/ther.2022.0048

Comparing Three Methods of Therapeutic Hypothermia Among Transported Neonates with Hypoxic–Ischemic Encephalopathy

2023· article· en· W4360804722 on OpenAlexaffabout
Sarfaraz Momin, Sumesh Thomas, Hussein Zein, James N. Scott, Lara M. Leijser, Sakeer Vayalthrikovil, Kamran Yusuf, Renee Paul, Alexandra Howlett, Khorshid Mohammad

Bibliographic record

VenueTherapeutic Hypothermia and Temperature Management · 2023
Typearticle
Languageen
FieldMedicine
TopicNeonatal and fetal brain pathology
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsMedicineHypothermiaHypoxic Ischemic EncephalopathyEncephalopathyAnesthesiaTertiary referral hospitalEmergency medicinePediatricsRetrospective cohort studySurgeryInternal medicine

Abstract

fetched live from OpenAlex

Hypoxic-ischemic encephalopathy (HIE) and associated multiorgan injury are significant causes of morbidity and mortality in term and near-term neonates. Therapeutic hypothermia (TH) is the current standard of care for neuroprotection in neonates with HIE. In our experience, the majority of babies born with HIE were found in nontertiary care facilities in our region, where effective methods of cooling during transport to tertiary care centers are desirable. Most centers initiate passive TH at referral hospitals, while active cooling is typically initiated during transport. The objective of this study was to evaluate the effectiveness of three methods of cooling during transport of neonates with HIE in southern Alberta. In this prospective cohort study, 186 neonates with HIE were transported between January 2013 and December 2021. Among the 186 neonates, 47 were passively cooled, 36 actively cooled with gel packs, and 103 cooled with a servo-controlled cooling device. The clinical characteristics were comparable for the three groups, with no difference in adverse events. Fifteen neonates (8%) died and 54 neonates (29%) suffered radiologically determined brain injury. Servo-controlled cooling was found to be superior to other methods in maintaining a target temperature without significant fluctuation during transport and with temperature in the target range on arrival at tertiary care facilities. The rate of overcooling was also lower in the servo-controlled group compared with other groups. There were no statistically significant differences between the groups in relation to mortality and brain MRI changes associated with HIE. Adjusting for GA, 10-minute Apgar score, base excess, HIE stage, and need for intubation during transport, passive cooling increased the odds of temperature fluctuation outside the range by 12-fold and gel pack cooling by 13-fold compared with servo-controlled cooling. The use of servo-controlled TH devices should be the preferred practice wherever feasible. (REB17-1334_REN3).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.882
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.273
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueTherapeutic Hypothermia and Temperature ManagementSame topicNeonatal and fetal brain pathologyFrench-language works237,207