MétaCan
Menu
Back to cohort
Record W4360977337 · doi:10.1016/j.bbiosy.2023.100076

Electrochemical and in vitro biological behaviors of a Ti-Mo-Fe alloy specifically designed for stent applications

2023· article· en· W4360977337 on OpenAlexafffund
Carolina Catanio Bortolan, Francesco Copes, Masoud Shekargoftar, Vinicius de Oliveira Fidelis Sales, Carlo Paternoster, Leonardo Contri Campanelli, Nicolas Giguère, Diego Mantovani

Bibliographic record

VenueBiomaterials and Biosystems · 2023
Typearticle
Languageen
FieldMaterials Science
TopicHydrogen embrittlement and corrosion behaviors in metals
Canadian institutionsUniversité Laval
FundersNatural Sciences and Engineering Research Council of CanadaFonds de recherche du Québec – Nature et technologiesConselho Nacional de Desenvolvimento Científico e TecnológicoCanada Foundation for InnovationMinistère de l'Économie, de la Science et de l'Innovation - Québec
KeywordsElectrochemistryAlloyMaterials scienceIn vitroNanotechnologyMetallurgyChemistryElectrodeBiochemistryPhysical chemistry

Abstract

fetched live from OpenAlex

There is a deep interest in developing new Ni-free Ti-based alloys to replace 316 L stainless steel and Co-Cr alloys for endovascular stent application, mainly because the release of Ni can generate toxicity and allergenicity. Interactions of Ti alloy biomaterials with bone cells and tissues have been widely investigated and reported, while interactions with vascular cells and tissues, such as endothelial cells (ECs) and smooth muscle cells (SMCs), are scarce. Therefore, this study focused on the relationship among the surface finishing features, corrosion behavior and in vitro biological performances regarding human ECs, SMCs and blood of a newly developed Ti-8Mo-2Fe (TMF) alloy, specifically designed for balloon-expandable stent applications. The alloy performances were compared to those of 316 L and pure Ti, prepared with the same surface finishing techniques, which are mechanical polishing and electropolishing. Surface properties were investigated by scanning electron microscopy (SEM), atomic force microscopy (AFM), contact angle (CA) and x-ray photoelectron spectroscopy (XPS). The corrosion behavior was assessed with potentiodynamic polarization (PDP) and electrochemical impedance spectroscopy (EIS) tests in phosphate buffered saline (PBS) solution. No significant differences were observed regarding the corrosion rate measured with PDP analyses, which was of the order of 2 × 10−4 mm/y for all the studied materials. Moreover, similarly to pure Ti, TMF exhibited an advantage over 316 L for biomedical applications, namely remarkable resistance to pitting corrosion up to high potentials. The results evidenced a good cytocompatibility and hemocompatibility, making this group of alloy a potential candidate for cardiovascular implants. In fact, both ECs and SMCs proliferated on TMF surfaces showing a 7-day viability similar to that of pure Ti. Regarding hemocompatibility, TMF did not cause hemolysis, and blood coagulation was delayed on its surface in comparison to pure Ti. When compared to 316 L, TMF showed similar hemocompatibility.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.504

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.284
Teacher spread0.246 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueBiomaterials and BiosystemsSame topicHydrogen embrittlement and corrosion behaviors in metalsFrench-language works237,207