MétaCan
Menu
Back to cohort
Record W4362634093 · doi:10.1016/j.ssci.2023.106154

Dorsal suspension in full-body harnesses: Comparison of perceived discomfort, pressure and physiological response

2023· article· en· W4362634093 on OpenAlexafffund
Bertrand Galy, Antoine Archambault, Marie-Anne Landry-Duval, Guillaume Montpetit, Denis Marchand, Chantal Gauvin, Jean Arteau, Yves Beauchamp

Bibliographic record

VenueSafety Science · 2023
Typearticle
Languageen
FieldHealth Professions
TopicBalance, Gait, and Falls Prevention
Canadian institutionsÉcole de Technologie SupérieureUniversité du Québec à MontréalMcGill UniversityInstitut de recherche Robert-Sauvé en santé et en sécurité du travail
FundersInstitut de Recherche Robert-Sauvé en Santé et en Sécurité du Travail
KeywordsSuspension (topology)DorsumEngineeringSimulationPhysical medicine and rehabilitationMedicineAnatomy

Abstract

fetched live from OpenAlex

Falls from height are still a major occupational hazard, particularly in the construction industry, where it is the leading cause of fatal injuries. When opting for personal fall arrest systems, the use of a safety harness is mandatory. Following a fall arrest, motionless suspension in a full-body harness can be hazardous and lead to death. This paper investigates the effect of harness type, gender, and somatotype on perceived discomfort, the pressure exerted by the harness straps, and the evolution of physiological parameters in motionless suspension. For this study, 30 male and 30 female students (10 ectomorph, 10 mesomorph, and 10 endomorph for each gender) were suspended for a maximum of ten minutes from the dorsal D-ring, in four different harnesses. The selected harnesses for this study are commercially available, one of them is X-configuration, another is Y-configuration, and the other two are the more traditional H-configuration. The results show that the H-configuration harnesses, which are very common in the industry and often the cheapest models, are perceived as the least tolerable in suspension. Moreover, H-configuration harnesses lead to greater reduction in muscular blood oxygenation and greater increase in the heart rate, which could make this type of harness hazardous. The Y-configuration harness seems to be the best performer in suspension. The influence of the sub-pelvic strap on suspension tolerance is not very clear and could be studied further. Those results could be useful to develop new harness models that would increase the suspension time tolerance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.410
Teacher spread0.357 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueSafety ScienceSame topicBalance, Gait, and Falls PreventionFrench-language works237,207