MétaCan
Menu
Back to cohort
Record W4366486083 · doi:10.1055/s-0043-1766283

Ansätze zur Volumenbestimmung von Meningeomen in der PET/CT Bildgebung mit dem neuartigen Tracer F-18-SiTATE

2023· article· de· W4366486083 on OpenAlexaff
Sophie Carina Kunte, Lena M. Unterrainer, Andreas Delker, Stephan H. Lindner, Matthias Brendel, Adrien Holzgreve, W. G. Kunz, CC Cyran, Jens Ricke, Klaus Jurkschat, Carmen Wängler, Björn Wängler, Ralf Schirrmacher, Maximilian Niyazi, J. C. Tonn, Leonie Beyer, Peter Bartenstein, Nathalie L. Albert, Marcus Unterrainer

Bibliographic record

VenueNuklearmedizin - NuclearMedicine · 2023
Typearticle
Languagede
FieldMedicine
TopicRadiopharmaceutical Chemistry and Applications
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsPhysicsNuclear medicineMedicine

Abstract

fetched live from OpenAlex

Ziel/Aim F-18-SiTATE ist ein neuartiges F-18-markiertes, an Somatostatinrezeptoren bindendes Peptid. Dieses etablierte sich bisher in der Bildgebung von NET. Da oftmals ein alleiniges MRT die ossäre Infiltration eines Meningeoms nicht beurteilen kann, kann das F-18-SiTATE PET/CT (bisher: Ga-68 markierte Somatostatin Analoga) aufgrund der Bindungseigenschaften hierfür genutzt werden. Ziel war die Etablierung einer standardisierte Methode zur Volumenbestimmung von Meningeomen, die bis dato nicht existiert, jedoch für die Planung von OP und Radiatio von großer Relevanz ist. Methodik/Methods Es wurden im CT gut abgrenzbare Meningeome (Volumen CT ≥1ml) ohne intraossäre Infiltration eingeschlossen. Nach Durchführung des SiTATE PET/CTs wurden die Volumina im CT (mit KM) bestimmt und dienten als volumetrische Referenz. Folgende Ansätze zur Volumenbestimmung im PET wurden verwendet und mit der CT korreliert: fester SUV-Wert, Isokontur Schwellenwertbildung abhängig vom SUV max (SUV%) und Schwellenwerte in Abhängigkeit von Knochenmark (SUV BM ), Parotis (SUV parotis ) und Hypophyse (SUV sella ). Ergebnisse/Results Es wurden 19 Meningeome eingeschlossen. Ein SUV-Wert von 4.0 ergab eine hohe Korrelation mit der Referenz (r=0.783, p<0.0001) und geringe Streuung im Bland-Altman-Plot. Die Korrelation durch Isokontur- sowie Referenzgewebe-basierte Schwellenwertbildung war niedriger oder die Streuung im Bland-Altman-Plot bei großen Läsionen größer. Schlussfolgerungen/Conclusions Die Verwendung eines SUV-Werts von 4.0 eignet sich aufgrund hoher Korrelation, Läsionsgrößen-unabhängiger geringer Streuung und nutzerfreundlicher Anwendung zur Volumenbestimmung von Meningeomen im SiTATE PET/CT. Diese kann in der klinischen Routine ohne spezielle technische Voraussetzungen und unabhängig von variabler SiTATE-Avidität in Referenzgeweben erfolgen. Patienten können durch Einsatz dieser Methodik in der klinischen Routine von besserer Therapieplanung profitieren. Publication History Article published online: 30 March 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart, Germany

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.344
Teacher spread0.296 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueNuklearmedizin - NuclearMedicineSame topicRadiopharmaceutical Chemistry and ApplicationsFrench-language works237,207