MétaCan
Menu
Back to cohort
Record W4367277081 · doi:10.1109/tim.2023.3270999

Portable Multiwavelength Fluorescence Measurement Device: Empirical Evaluation

2023· article· en· W4367277081 on OpenAlexafffund
Raphael Hagen, Daniel Fehr, Fabrizio Spano, Samuel Babity, Davide Brambilla, Mathias Bonmarin

Bibliographic record

VenueIEEE Transactions on Instrumentation and Measurement · 2023
Typearticle
Languageen
FieldMedicine
TopicOptical Imaging and Spectroscopy Techniques
Canadian institutionsUniversité de Montréal
FundersNatural Sciences and Engineering Research Council of CanadaFonds de recherche du Québec
KeywordsPhotodiodeDiffuser (optics)LaserOptoelectronicsFluorescenceMaterials scienceOpticsPhotocurrentLaser diodeOptical powerLight-emitting diodeDiodePhysicsLight source

Abstract

fetched live from OpenAlex

Monitoring-based preventive medicine relies heavily on minimal or noninvasive, portable, and cost-effective measurement solutions. In this study, we present a handheld multiwavelength fluorescence measurement system for detection of dermally injected fluorescent tracers. The circular detection area of the device is positioned on the sample containing the fluorescent marker. The marker is excited at regular intervals by a pulse of light. The optical output power is controlled by a laser diode driver, which receives direct feedback on the emitted light intensity from the monitor photodiode integrated into the laser diode package. An optical diffuser is located in front of each laser diode to ensure uniform illumination of the measurement area. Pulsed excitation of the fluorescent tracer allows alternate measurement of foreground and background light intensity. By subtracting the background from the foreground and using a switched-input photocurrent measurement technique, the measured photocurrent represents the actual light emission from the marker. The instrument has interchangeable modules that contain the excitation electronics and emission filter. These modules allow the instrument to be configured for a variety of different fluorescent markers. In vitro measurements show that the device is capable of performing fluorescence measurements for its intended use as a point-of-care device in preventive medicine.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.673
Threshold uncertainty score0.668

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.148
GPT teacher head0.389
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Instrumentation and MeasurementSame topicOptical Imaging and Spectroscopy TechniquesFrench-language works237,207