MétaCan
Menu
Back to cohort
Record W4379875988 · doi:10.1136/rmdopen-2023-003074

Joint distraction using a purpose-built device for knee osteoarthritis: a prospective 2-year follow-up

2023· article· en· W4379875988 on OpenAlexfundaboutno aff
T. Struik, S.C. Mastbergen, Reinoud W. Brouwer, Roel J.H. Custers, Rutger C. I. van Geenen, Christiaan H. W. Heusdens, Pieter J. Emans, Maarten R. Huizinga, Mylène P. Jansen

Bibliographic record

VenueRMD Open · 2023
Typearticle
Languageen
FieldMedicine
TopicOsteoarthritis Treatment and Mechanisms
Canadian institutionsnot available
FundersUniversitair Medisch Centrum UtrechtZonMwArthritis SocietyReumaNederlandDutch Arthritis Society
KeywordsMedicineOsteoarthritisDistractionAdverse effectArthroplastyRadiographySurgeryProspective cohort studyKnee painPhysical therapyInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVE: Knee distraction treatment for end-stage osteoarthritis successfully postpones arthroplasty for years. Studies performed thus far used general intended use, patient-personalised or custom-made devices. In this study, for the first time, a device specifically designed for knee distraction is evaluated. DESIGN: 65 patients (≤65 years) with end-stage knee osteoarthritis indicated for arthroplasty received knee distraction. Before, 1-year and 2-year post-treatment, questionnaires were filled out and knee radiographs made. Adverse events and self-reported pain medication were registered. RESULTS: Forty-nine patients completed 2-year follow-up: one patient did not complete treatment, three patients received arthroplasty in the first and four patients in the second year follow-up. Eight patients were lost to follow-up in the second year. The total Western Ontario and McMaster Universities Osteoarthritis Index score showed a clinically relevant improvement at 1 and 2 years (+26 and +24 points), as did all subscales (all p<0.001). The minimum radiographic joint space width improved over 1 (+0.5 mm; p<0.001) and 2 (+0.4 mm; p=0.015) years, as did the physical Short-Form 36 (+10 points; p<0.001). The most common adverse event was pin tract infection, experienced by 66% of patients, in 88% successfully treated with oral antibiotics. In two cases, hospitalisation and/or intravenous antibiotics were needed. Eight patients experienced device-related complications. None of the complications influenced 2-year outcomes. Before treatment, 42% of patients used pain medication, which had nearly been halved 1 (23%; p=0.02) and 2 years (29%; p=0.27) post-treatment. CONCLUSIONS: Patients treated with a general applicable, for knee distraction purpose-built device showed, despite adverse events, significant clinical and structural improvement over 2 years. TRIAL REGISTRATION NUMBER: NL7986.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.598
Threshold uncertainty score0.794

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.072
GPT teacher head0.337
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueRMD OpenSame topicOsteoarthritis Treatment and MechanismsFrench-language works237,207