MétaCan
Menu
Back to cohort
Record W4381848132 · doi:10.1002/ccd.30752

Anatomic suitability for transapical transcatheter mitral valve implantation using a tether‐based device

2023· article· en· W4381848132 on OpenAlexaff
Philipp Blanke, Thomas Modine, Alison Duncan, Maurizio Taramasso, Nicolas Dumonteil, Michael L. Chuang, Lenard Conradi

Bibliographic record

VenueCatheterization and Cardiovascular Interventions · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsSt. Paul's HospitalUniversity of British Columbia
Fundersnot available
KeywordsMedicineVentricular outflow tractMitral valveMultisliceSystoleCardiologyVentricular outflow tract obstructionDiastoleRadiologyCardiac cycleInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Transcatheter mitral valve implantation (TMVI) is a novel therapeutic option for treating symptomatic mitral valve disease. Evaluating patient anatomical suitability is a critical step in the TMVI screening process, but currently requires specialized software and computerized device models. AIMS: This analysis sought to assess the effectiveness of simple and standardized multislice computed tomography (MSCT) anatomic measurements for their ability to discriminate between patients who passed anatomical screening for Tendyne™ TMVI. METHODS: Subjects screened for the Tendyne Expanded Clinical Study from January 2016 through September 2019 were included. Core laboratory screening measurements included mitral annular (MA) dimensions at end-systole and end-diastole, simulated device implantation, and neo-left ventricular outflow tract (LVOT) area. Additionally, nine standard measurements of patient anatomy were assessed for their predictive value of patients passing the anatomic screening process. RESULTS: Out of 496 subjects screened for eligibility, 257 subjects met clinical eligibility criteria with MA dimensions within the manufacturer's suggested range: 153 (59.5%) underwent TMVI while 104 (40.5%) were excluded from the study for other anatomic reasons (76% due to risk of LVOT obstruction). CT-derived left ventricular end-systole diameter (LVESD) had the highest discriminatory power for predicting TMVI anatomical suitability (area under the curve of 0.908, p < 0.0001). The mitral inter-commissural (IC) dimension was best predictive of annular dimensions being within range, with dimensions <30 or >50 mm resulting in a negative predictive value of 94.4%. CONCLUSIONS: MSCT-derived mitral IC dimension and LVESD easily performed measures that are effective predictors of anatomical suitability or screen failure for this tether-based TMVI device.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (broad)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.409
Threshold uncertainty score0.990

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.020
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.066
GPT teacher head0.385
Teacher spread0.319 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueCatheterization and Cardiovascular InterventionsSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207