MétaCan
Menu
Back to cohort
Record W4381850727 · doi:10.3171/2023.3.spine2329

Robot-assisted percutaneous pedicle screw placement accuracy compared with alternative guidance in lateral single-position surgery: a systematic review and meta-analysis

2023· review· en· W4381850727 on OpenAlexaboutno aff
Neal Patel, Cathleen C. Kuo, Zach Pennington, Nolan J. Brown, Julian Gendreau, Rohin Singh, Shane Shahrestani, Candler Boyett, Luis Daniel Diaz-Aguilar, Martin H. Pham

Bibliographic record

VenueJournal of Neurosurgery Spine · 2023
Typereview
Languageen
FieldMedicine
TopicIntraoperative Neuromonitoring and Anesthetic Effects
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineMeta-analysisCochrane LibraryMEDLINEFluoroscopyPercutaneousMedical physicsSystematic reviewChecklistSurgery

Abstract

fetched live from OpenAlex

OBJECTIVE: While single-position surgery (SPS) eliminates the need for patient repositioning, the placement of screws in the unconventional lateral position poses unique challenges related to asymmetry relative to the surgical table. Use of robotic guidance or intraoperative navigation can help to overcome this. The aim of this study was to compare the relative accuracies offered by these various navigation modalities for pedicle screws placed in lateral SPS. METHODS: According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, the PubMed/Medline, Embase, and Cochrane Library databases were queried for studies reporting pedicle screw placement accuracy using fluoroscopic, CT-navigated, O-arm, or robotic guidance in lateral SPS, and a systematic review and meta-analysis was performed. Included studies all compared evaluated screw placement accuracy in lateral SPS using a single navigation method. Quality assessment was performed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system; risk of bias was assessed using the Newcastle-Ottawa Scale and the Joanna Briggs Institute checklist. The primary outcome, rate of pedicle screw breach, was analyzed using random-effects meta-analysis. RESULTS: Eleven studies were included comprising 548 patients who underwent the placement of instrumentation with 2488 screws. For the fluoroscopic, CT-navigated, O-arm, and robotic guidance cohorts, there were 3, 2, 3, and 3 studies, respectively. Breach rates by modality were as follows: fluoroscopic guidance (6.6%), CT navigation (4.7%), O-arm (3.9%), and robotic guidance (3.9%). Random-effects meta-analysis showed a significant difference between studies, with an overall breach rate of 4.9% (95% CI 3.1%-7.5%; p < 0.001); however, testing for subgroup differences failed to show a significant difference between guidance modalities (QM = 0.69, df = 3; p = 0.88). Heterogeneity between studies was significant (I2 = 79.0%, τ2 = 0.41, χ2 = 47.65, df = 10; p < 0.001). CONCLUSIONS: Robotic guidance of screws is noninferior to alternative guidance modalities in lateral SPS; however, additional prospective studies directly comparing different guidance types are merited.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.017
metaresearch head score (Gemma)0.047
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.019
Threshold uncertainty score0.088

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0170.047
Meta-epidemiology (narrow)0.0030.002
Meta-epidemiology (broad)0.0190.038
Bibliometrics0.0070.008
Science and technology studies0.0010.001
Scholarly communication0.0040.002
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.141
GPT teacher head0.369
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Neurosurgery SpineSame topicIntraoperative Neuromonitoring and Anesthetic EffectsFrench-language works237,207