Commissioning of a solid tank design for fan-beam optical CT based 3D radiation dosimetry

2023· article· en· W4384296355 on OpenAlexafffund
A Ogilvy, Scott Collins, Michelle Hilts, Warren Hare, Andrew Jirasek

Bibliographic record

VenuePhysics in Medicine and Biology · 2023
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsBC Cancer AgencyKelowna General HospitalOkanagan University CollegeUniversity of British Columbia, Okanagan CampusUniversity of British Columbia
FundersCanadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada
KeywordsScannerImaging phantomImage resolutionOpticsComputer scienceDosimetryMaterials scienceNuclear medicinePhysicsMedicine

Abstract

fetched live from OpenAlex

Abstract Objective. Optical computed tomography (CT) is one of the leading modalities for imaging gel dosimeters used in the verification of complex radiotherapy treatments. In previous work, a novel fan-beam optical CT scanner design was proposed that could significantly reduce the volume of the refractive index baths that are commonly found in optical CT systems. Here, the proposed scanner has been manufactured and commissioned. Approach. Image reconstruction is performed through algebraic reconstruction technique and iterated using the fast iterative shrinkage-thresholding algorithm (FISTA) algorithm. Ray tracing for algebraic reconstruction was performed using an in-house developed ray tracing simulator. A set of Sylgard® 184 phantoms were created to commission spatial resolution, geometric deformity, contrast-to-noise ratio (CNR), and scan settings. Main Results. The scanner is capable of a 0.929 mm −1 spatial resolution, observed at 200 iterations, although the spatial resolution is highly dependent on the number of iterations. The geometric distortion, measured by scanning a needle phantom with the prototype scanner as well as a conventional x-ray CT was found to be within <0.25 mm. The CNR was found to peak between 65 and 190 occurring between 50 and 100 iterations and was highly dependent on the region chosen for background noise calculation. The proposed scanner is capable of scanning and reading out slices in less than 1 min per slice. Significance. This work displays the viability of a fan-beam optical CT scanner with minimal index matching using ray-traced algebraic reconstruction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.127
GPT teacher head0.425
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2023
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and Biology→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→