Thermal Profiles for Focal Pulsed Electric Field Ablation
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND: Pulsed electrical field (PEF) ablation may cause tissue heating. These changes are reportedly small, but each PEF system and waveform will have a different behavior, and data are lacking. OBJECTIVES: This study sought to compare the temperature profile of focal point, monopolar biphasic PEF ablation versus radiofrequency (RF). METHODS: Ablation lesions were performed on perfused thigh muscle of swine. PEF lesions were performed with 3 compatible ablation catheters at the highest (25 amp) energy, and 1 catheter (Tacticath SE) was also used at the 22- and 19-amp levels. Temperature changes in the tissue were measured using fluoroptic temperature probes inserted at the muscle surface, as well as 3 mm and 7 mm below the surface. Temperatures were recorded continuously at baseline, during delivery, and after ablation. Muscle temperatures were compared with those of RF lesions performed with 1 catheter (Tacticath SE) at 30 W for 30 seconds. RESULTS: PEF ablation with 3energy settings produced small temperature changes. Maximum average temperature rise for PEF for the maximum (25-amp) energy setting (32 lesions) was 7.6 °C, 2.8 °C, and 0.9 °C at the surface, 3-mm depth, and 7-mm depth, respectively. The temperature rise was dose dependent, with lower energy settings yielding less temperature rise. RF ablations (10 lesions) produced temperature increases of 16.6 °C, 39.8 °C, and 9.5 °C at the surface, 3-mm depth, and 7-mm depth, respectively. CONCLUSIONS: PEF caused detectable temperature changes in muscle tissue, which never exceeded 2.8 °C at the 3-mm depth versus baseline. By contrast, RF produced substantial temperature rises. These data support that focal monopolar biphasic energy delivered by this PEF technology retains a favorable thermal safety profile.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it