MétaCan
Menu
Back to cohort
Record W4385666709 · doi:10.1038/s41467-023-40539-9

Spying on parahydrogen-induced polarization transfer using a half-tesla benchtop MRI and hyperpolarized imaging enabled by automation

2023· article· en· W4385666709 on OpenAlexaff
Frowin Ellermann, A. Sirbu, Arne Brahms, Charbel D. Assaf, Rainer Herges, Jan‐Bernd Hövener, Andrey N. Pravdivtsev

Bibliographic record

VenueNature Communications · 2023
Typearticle
Languageen
FieldChemistry
TopicAdvanced NMR Techniques and Applications
Canadian institutionsWestern University
FundersBundesministerium für Bildung und ForschungEuropean Regional Development FundDeutsche ForschungsgemeinschaftDeutscher Akademischer Austauschdienst
KeywordsHyperpolarization (physics)Spin isomers of hydrogenPolarizerNuclear magnetic resonanceInduced polarizationPolarization (electrochemistry)Materials scienceChemistryPhysicsOpticsNuclear magnetic resonance spectroscopyPhysical chemistry

Abstract

fetched live from OpenAlex

Abstract Nuclear spin hyperpolarization is a quantum effect that enhances the nuclear magnetic resonance signal by several orders of magnitude and has enabled real-time metabolic imaging in humans. However, the translation of hyperpolarization technology into routine use in laboratories and medical centers is hampered by the lack of portable, cost-effective polarizers that are not commercially available. Here, we present a portable, automated polarizer based on parahydrogen-induced hyperpolarization (PHIP) at an intermediate magnetic field of 0.5 T (achieved by permanent magnets). With a footprint of 1 m 2 , we demonstrate semi-continuous, fully automated 1 H hyperpolarization of ethyl acetate- d6 and ethyl pyruvate- d6 to P = 14.4% and 16.2%, respectively, and a 13 C polarization of 1- 13 C-ethyl pyruvate- d6 of P = 7%. The duty cycle for preparing a dose is no more than 1 min. To reveal the full potential of 1 H hyperpolarization in an inhomogeneous magnetic field, we convert the anti-phase PHIP signals into in-phase peaks, thereby increasing the SNR by a factor of 5. Using a spin-echo approach allowed us to observe the evolution of spin order distribution in real time while conserving the expensive reagents for reaction monitoring, imaging and potential in vivo usage. This compact polarizer will allow us to pursue the translation of hyperpolarized MRI towards in vivo applications further.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.317
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueNature CommunicationsSame topicAdvanced NMR Techniques and ApplicationsFrench-language works237,207