2023· article· en· W4385724439 on OpenAlexaffabout
Josh Greenberg, Heather Edwards, Allison Biggar, Nicholas Gan, Heather Jefferson

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicGeophysical Methods and Applications
Canadian institutionsRegional Municipality of Ottawa
Fundersnot available
KeywordsComputer science

Abstract

fetched live from OpenAlex

Over the past 15 years, the Region of Peel in Southern Ontario has been developing an extensive condition assessment program for its large diameter prestressed concrete cylinder pipe feedermains. The proactive assessment and repair of critical feedermains helps assure that the Region can deliver safe and reliable drinking water to its customers every day. The Herridge 1,500-mm (60-in.) feedermain is approximately 6 km (3.7 mi) in length and was first assessed using electromagnetic inspection technology in conjunction with a visual and sounding inspection in 2011. This inspection identified a significantly higher-than-average degradation rate for prestressed concrete cylinder pipe (PCCP), with 6.2% of pipes exhibiting signs of broken prestressing wire wraps, particularly along a critical trucking route with heavy traffic loading and an adjacent rail corridor. From 2014 through 2016, the Region undertook an extensive repair program of the Herridge Feedermain, repairing 106 pipes throughout the length of the feedermain with carbon fiber reinforced polymer (CFRP). Repairs were completed before the introduction of American Water Works Association C305 standard and included both composite and stand-alone designs to reinforce distressed pipes. A follow-up electromagnetic and visual and sounding inspection in 2021 also included a detailed inspection of the CFRP repairs to assess their long-term durability. The electromagnetic inspection confirmed continued high rates of degradation, with 6.2% of all pipes exhibiting signs of broken prestressing wire wraps in 2011, and an additional 2.8% exhibiting signs of broken prestressing wire wraps in 2021. Inspection of the CFRP repairs concluded that the stand-alone designs had held up well; however, structural issues were found in several composite repaired pipes as well as new pipes. This led to upgrades in 2022 for the damaged and most at-risk composite pipes to the stand-alone design to increase the expected lifespan of the repairs. Additionally new repairs were completed for a handful of pipes that had experienced new or growing amounts of broken prestressing wires since 2011. The 2021 condition assessment also featured the addition of inspection and maintenance on all in-line butterfly valves in the feedermain, including entering the pipe where possible to inspect the valve gaskets and seats. The valve maintenance program ensured that valves are operable in an emergency and was completed at a fraction of the price of valve replacement. The Region’s long-term management of the Herridge Feedermain, including electromagnetic inspections, planned CFRP repairs during future outages, and valve maintenance program is helping to achieve system reliability and honor the commitment to customers of delivering clean, safe drinking water.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Theoretical or conceptual · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.788
Threshold uncertainty score0.187

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.374
Teacher spread0.327 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designTheoretical or conceptual
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes2
Has abstractyes

Explore more

Same topicGeophysical Methods and ApplicationsFrench-language works237,207