MétaCan
Menu
Back to cohort
Record W4386070840 · doi:10.11159/eee23.113

Development of an Optofluidic System for Concentration Measurement of Colorimetric based Solution targeted for Water Quality Assessment

2023· article· en· W4386070840 on OpenAlexvenueno aff
Fatin Izyani Mohamad Robi, Mohd Rumaizan Maidan Dali, Khairul Azman Ahmad, Saiful Zaimy Yahaya, Yahaya AbdRahman

Bibliographic record

VenueProceedings of the World Congress on Electrical Engineering and Computer Systems and Science · 2023
Typearticle
Languageen
FieldEnvironmental Science
TopicWater Quality Monitoring and Analysis
Canadian institutionsnot available
Fundersnot available
KeywordsQuality (philosophy)Computer scienceWater qualityMaterials scienceProcess engineeringEnvironmental scienceEngineeringPhysics

Abstract

fetched live from OpenAlex

Concentration measurement of a solution based on colorimetric method is normally performed using a commercial and bulky device such as colorimeter and spectrometer.This approach has several drawbacks: the sample needs to be manually taken, transported and tested in laboratory, as well as it requires large volume of analyte and reagent.Such problem can be overcome by having a small and compact system such as optofluidic based device with the capability of carrying out colorimetric measurements with better operational processes.Therefore, this research focuses on the development of a smaller optofluidic based system to measure the concentration of colorimetric based solutions.The system consists of a microfluidic platform combined with a light emitting diode (LED) and a lightdependent resistor (LDR) as its optical source and detector, respectively.Based on Beers law principles, different concentration of coloured solution produces different voltage signal and absorbance effect, which is then being processed and manipulated to produce the concentration measurement.The optofluidic system was then tested on colorimetric solution between 0.1M to 1M and gives linearity coefficient, R 2 of 0.9977 and 0.9979 for its voltage and absorbance, respectively.The proposed optofluidic system is targeted to be able to measure the concentration of particles in colorimetric solution and to be implemented for colorimetric based water quality assessment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.517
Threshold uncertainty score0.247

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.258
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of the World Congress on Electrical Engineering and Computer Systems and ScienceSame topicWater Quality Monitoring and AnalysisFrench-language works237,207