A randomized crossover comparison of the bébé VieScope and direct laryngoscope for pediatric airway management by nurses in medical simulation settings

2023· article· en· W4386438082 on OpenAlexaff
Paweł Wieczorek, Michał Pruc, Maciej Janusz Krajsman, Wojciech Wieczorek, Başar Cander, Łukasz Szarpak, Alla Navolokina, Michał Matuszewski, Michal Zyla, Nicola Luigi Bragazzi, Jacek Smereka

Bibliographic record

VenueExpert Review of Medical Devices · 2023
Typearticle
Languageen
FieldMedicine
TopicAirway Management and Intubation Techniques
Canadian institutionsYork University
Fundersnot available
KeywordsMedicineAirway managementIntubationAirwayGlottisRandomized controlled trialAnesthesiaEndotracheal intubationLaryngoscopesTracheal intubationSurgeryLarynx

Abstract

fetched live from OpenAlex

BACKGROUND: Airway management in life-threatening emergencies is essential for children, and endotracheal intubation is the gold standard. It protects against regurgitation and enables mechanical ventilation. New types of airway management equipment are being developed and implemented to meet the needs of medical personnel. RESEARCH DESIGN AND METHODS: This prospective, randomized, cross-over simulation trial evaluated the success of endotracheal intubation in three scenarios: normal airway (scenario-A), tongue edema (scenario-B), and continuous chest compression (scenario-C), using the bébé Vie Scope™ laryngoscope (VieScope) and the Macintosh blade laryngoscope (MAC) as a comparative tool performed by nurses with limited tracheal intubation experience. RESULTS: The results of the study showed that in scenario-A, there were no significant differences in the first attempt success rate or endotracheal intubation time between VieScope and MAC. However, VieScope was associated with better visualization of the glottis. In scenarios B and C, VieScope was significantly more effective than MAC in terms of first-pass success rate, time to intubate, Cormack-Lehane grade, POGO score, and ease of endotracheal intubation. CONCLUSIONS: Bébé VieScope may be useful for endotracheal intubation in pediatric patients, particularly in cases of tongue edema and ongoing chest compression, providing a higher first-pass success rate than conventional laryngoscopes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.006
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0030.001
Bibliometrics0.0010.000
Science and technology studies0.0010.002
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.403
Teacher spread0.386 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueExpert Review of Medical DevicesSame topicAirway Management and Intubation TechniquesFrench-language works237,207