MétaCan
Menu
Back to cohort

Multitone Microwave Frequency Locking to a Noisy Cavity via Real-Time Feedback

2023· article· en· W4386476036 on OpenAlexfundno aff
Jean-Paul van Soest, C. A. Potts, S. Peiter, A. Sanz Mora, Gary A. Steele

Bibliographic record

VenuePhysical Review Applied · 2023
Typearticle
Languageen
FieldPhysics and Astronomy
TopicMechanical and Optical Resonators
Canadian institutionsnot available
FundersNatural Sciences and Engineering Research Council of CanadaNederlandse Organisatie voor Wetenschappelijk OnderzoekEuropean Commission
KeywordsMicrowave cavityMicrowavePhysicsBandwidth (computing)OptomechanicsNoise (video)Injection lockingAcousticsOpticsComputer scienceResonatorTelecommunications

Abstract

fetched live from OpenAlex

Microwave cavities are commonly used in many experiments, including optomechanics, magnetic field sensing, magnomechanics, and circuit quantum electrodynamics. Noise, such as variations in the magnetic field or mechanical vibrations, can cause fluctuations of the natural frequency of the cavity, creating challenges in operating them in experiments. To overcome these challenges, we demonstrate a dynamic feedback system implemented by the locking of a microwave drive to the noisy cavity. A homodyne-interferometer scheme monitors the cavity resonance fluctuations due to low-frequency noise, which is mitigated by frequency modulating the microwave generator. The feedback has a bandwidth of 400 Hz, with a reduction of cavity fluctuations by $85\mathrm{%}$ integrating up to a bandwidth of 2 kHz. Moreover, the cavity resonance frequency fluctuations are reduced by $73\mathrm{%}$. This scheme can be scaled to enable multitone experiments locked to the same feedback signal. As a demonstration, we apply the feedback to an optomechanical experiment and implement a cavity-locked multitone mechanical measurement. As low-frequency cavity frequency noise can be a limiting factor in many experiments, the multitone microwave locking technique presented here is expected to be relevant for a wide range of microwave-cavity experiments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.288
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venuePhysical Review AppliedSame topicMechanical and Optical ResonatorsFrench-language works237,207