The effect of contaminating media on the static and dynamic mechanical resilience of dental implant abutments' screws: In vitro study

2023· article· en· W4386503593 on OpenAlexvenueno aff
Keren Shemtov‐Yona, A. Arieli, Mohana Barhum, Raphael Pilo, Shifra Levartovsky

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2023
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsAbutmentMaterials scienceTorqueDynamic loadingDentistryDental AbutmentsDental implantImplantComposite materialOrthodonticsStructural engineeringEngineeringMedicineSurgery

Abstract

fetched live from OpenAlex

INTRODUCTION: This in vitro study aims to biomechanically evaluate the influence of medium contamination for example, saliva, blood, chlorhexidine (liquid and gel), and fluoride mouthwash on the biomechanical behavior of implant abutments' screws under static and dynamic loading. METHODS: Forty five Ti6Al4V commercial dental implants and abutments were tested in this study. Two main mechanical tests were carried out in the selected media. The first, static, aimed to evaluate the torque loss after the first tightening. The second, dynamic, involved a random cyclic load range between 0 and 200 N to evaluate torque loss due to mastication. In addition, metallographic longitudinal and cross-sections of the abutment-implant apparatus were examined to evaluate the abutment screw-abutment-implant interface. RESULTS: The static torque test showed that irrespective of the media, no statistical difference in static torque loss was found prior to dynamic loading. For the dynamic tests, torque-angle evolution analysis during tightening to 30 Ncm and after the spectrum loading, showed the same global mechanical behavior for all media, but the statistical analysis indicated a difference between the groups in reverse torque values (RTV) and in the torque loss due to dynamic loading. The medium groups CHX, CHX-gel, and Fluoride mouthwash, showed a meaningful torque loss due to loading, but the medium groups, control (no medium), blood and saliva showed an opposite trend and required a higher torque to open the abutment screws. The microstructural analysis revealed clear signs of cold-welding/galling, post-dynamic loading in these latter groups. CONCLUSIONS: The presence of lubrication/contamination media (CHX mouthwash/CHX-gel/Fluoride mouthwash) reduces the preload generated due to tightening but prevents damage due to galling. The observed reduction of RTV clearly emphasizes the need for frequent abutment screw retightening for implant-supported prosthetic long-term stability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.063
GPT teacher head0.461
Teacher spread0.398 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→