MétaCan
Menu
Back to cohort
Record W4386614420 · doi:10.1002/mrm.29875

Current methods for hyperpolarized [<scp>1‐<sup>13</sup>C</scp>]pyruvate <scp>MRI</scp> human studies

2024· review· en· W4386614420 on OpenAlexaff
Peder E. Z. Larson, Jenna Bernard, James A. Bankson, Nikolaj Bøgh, Robert Bok, Albert P. Chen, Charles H. Cunningham, Jeremy W. Gordon, Jan‐Bernd Hövener, Christoffer Laustsen, Dirk Mayer, Mary A. McLean, Franz Schilling, James B. Slater, Jean‐Luc Vanderheyden, Cornelius von Morze, Daniel B. Vigneron, Duan Xu

Bibliographic record

VenueMagnetic Resonance in Medicine · 2024
Typereview
Languageen
FieldChemistry
TopicAdvanced NMR Techniques and Applications
Canadian institutionsUniversity of TorontoSunnybrook Health Science Centre
FundersNational Institute of Biomedical Imaging and BioengineeringNational Institutes of HealthNational Cancer InstituteChang Gung Medical FoundationEidgenössische Technische Hochschule ZürichAlbert-Ludwigs-Universität FreiburgUniversity of Texas MD Anderson Cancer CenterMemorial Sloan-Kettering Cancer CenterInstitute for Bioengineering of CataloniaUniversity of OxfordDanmarks Tekniske UniversitetAarhus UniversitetTechnische Universität München
KeywordsComputer scienceGlycolysisKey (lock)MedicineNuclear magnetic resonanceNuclear medicineChemistryMedical physicsPhysicsMetabolismInternal medicine

Abstract

fetched live from OpenAlex

Abstract MRI with hyperpolarized (HP) 13 C agents, also known as HP 13 C MRI, can measure processes such as localized metabolism that is altered in numerous cancers, liver, heart, kidney diseases, and more. It has been translated into human studies during the past 10 years, with recent rapid growth in studies largely based on increasing availability of HP agent preparation methods suitable for use in humans. This paper aims to capture the current successful practices for HP MRI human studies with [1‐ 13 C]pyruvate—by far the most commonly used agent, which sits at a key metabolic junction in glycolysis. The paper is divided into four major topic areas: (1) HP 13 C‐pyruvate preparation; (2) MRI system setup and calibrations; (3) data acquisition and image reconstruction; and (4) data analysis and quantification. In each area, we identified the key components for a successful study, summarized both published studies and current practices, and discuss evidence gaps, strengths, and limitations. This paper is the output of the “HP 13 C MRI Consensus Group” as well as the ISMRM Hyperpolarized Media MR and Hyperpolarized Methods and Equipment study groups. It further aims to provide a comprehensive reference for future consensus, building as the field continues to advance human studies with this metabolic imaging modality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesMeta-epidemiology (narrow)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.926
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0040.001
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.098
GPT teacher head0.469
Teacher spread0.372 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations49
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced NMR Techniques and ApplicationsFrench-language works237,207