Simultaneous detection of trace Pb(II) and Cd(II) cations in ore samples by anodic stripping analysis using pMO/erGO‐modified glassy carbon electrodes
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
Abstract Environmental safety is of paramount importance for human well‐being, imposing significant demands for affordable, rapid, portable, and robust analytical tools for real‐time and on‐site water monitoring. In this context, we have developed an analytical method to efficiently detect heavy metal ions, particularly Pb 2+ ions, in water samples. This method employs a stepwise‐prepared electrode comprised of a thin film of poly(methyl orange) (pMO) electrochemically deposited onto reduced graphene oxide (erGO), which is in turn coated on a glassy carbon electrode (GCE). The resulting pMO/erGO/GCE electrode was characterized using Raman spectroscopy, scanning electron microscopy (SEM), and electrochemical techniques. Square wave anodic stripping voltammetry (SWASV) was subsequently employed to detect the target ions. Importantly, the pMO/erGO/GCE electrode exhibits excellent analytical performance, featuring a broad linear concentration range spanning from 14 to 595 parts per billion (ppb), a sensitivity of 5.60 μA ppb −1 cm −2 , and a theoretical calculated value of the detection limit of 0.82 ppb. The effectiveness of this sensor was validated through successful testing of aqueous samples from dissolved ores containing both lead(II) and cadmium(II) cations, as determined by atomic absorption spectroscopy.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.010 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it