MétaCan
Menu
Back to cohort
Record W4387003135 · doi:10.1159/000533573

Proceedings of the 2022 UAB CRRT Academy: Non-Invasive Hemodynamic Monitoring to Guide Fluid Removal with CRRT and Proliferation of Extracorporeal Blood Purification Devices

2023· review· en· W4387003135 on OpenAlex
J. Pedro Teixeira, Amanda Dijanic Zeidman, William Beaubien‐Souligny, Jorge Cerdá, Michael Connor, Katrina Eggleston, Luis A. Juncos, J. Ricardo Da Silva, Catherine Wells, Lenar Yessayan, Andrew B. Barker, Wendy McConville, Rajesh Speer, Keith Wille, Javier A. Neyra, Ashita Tolwani

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueBlood Purification · 2023
Typereview
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsCentre Hospitalier de l’Université de Montréal
Fundersnot available
KeywordsRenal replacement therapyMedicineIntensive care medicineNephrologyIntravascular volume statusExtracorporealHemodynamicsHemofiltrationIntensive care unitCardiologyInternal medicineHemodialysis

Abstract

fetched live from OpenAlex

In 2022, we celebrated the 15th anniversary of the University of Alabama at Birmingham (UAB) Continuous Renal Replacement Therapy (CRRT) Academy, a 2-day conference attended yearly by an international audience of over 100 nephrology, critical care, and multidisciplinary trainees and practitioners. This year, we introduce the proceedings of the UAB CRRT Academy, a yearly review of select emerging topics in the field of critical care nephrology that feature prominently in the conference. First, we review the rapidly evolving field of non-invasive hemodynamic monitoring and its potential to guide fluid removal by renal replacement therapy (RRT). We begin by summarizing the accumulating data associating fluid overload with harm in critical illness and the potential for harm from end-organ hypoperfusion caused by excessive fluid removal with RRT, underscoring the importance of accurate, dynamic assessment of volume status. We describe four applications of point-of-care ultrasound used to identify patients in need of urgent fluid removal or likely to tolerate fluid removal: lung ultrasound, inferior vena cava ultrasound, venous excess ultrasonography, and Doppler of the left ventricular outflow track to estimate stroke volume. We briefly introduce other minimally invasive hemodynamic monitoring technologies before concluding that additional prospective data are urgently needed to adapt these technologies to the specific task of fluid removal by RRT and to learn how best to integrate them into practical fluid-management strategies. Second, we focus on the growth of novel extracorporeal blood purification devices, starting with brief reviews of the inflammatory underpinnings of multiorgan dysfunction and the specific applications of pathogen, endotoxin, and/or cytokine removal and immunomodulation. Finally, we review a series of specific adsorptive technologies, several of which have seen substantial clinical use during the COVID-19 pandemic, describing their mechanisms of target removal, the limited existing data supporting their efficacy, ongoing and future studies, and the need for additional prospective trials.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.664
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.321
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it