MétaCan
Menu
Back to cohort
Record W4387230446 · doi:10.3390/atmos14101520

Indoor Air Purifiers in the Fight against Airborne Pathogens: The Advantage of Circumferential Outflow Diffusers

2023· article· en· W4387230446 on OpenAlexafffund
Yevgen Nazarenko, Chitra Narayanan, Parisa A. Ariya

Bibliographic record

VenueAtmosphere · 2023
Typearticle
Languageen
FieldMedicine
TopicInfection Control and Ventilation
Canadian institutionsMcGill University
FundersNatural Sciences and Engineering Research Council of CanadaMitacsMcGill UniversityUniversity of Cincinnati
KeywordsOutflowAirflowAir purifierMistDeflection (physics)Environmental scienceDiffuser (optics)Deflection angleMeteorologyOpticsInletPhysicsEngineeringMechanical engineering

Abstract

fetched live from OpenAlex

Airborne particles containing pathogens such as bacteria (e.g., M. tuberculosis) or virions (e.g., influenza or severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)) can cause infections. It has been speculated that the outflow from indoor air purifiers with a directional outlet could entrain and spread pathogen-containing aerosol particles. To date, only the case of indoor air purifiers with a directional outflow has been considered, and here we investigate an indoor air purifier with a circumferential outflow diffuser—an alternative design solution that is already commercially available. We measured the airflow velocity at two different angles to the surface of the circumferential outflow diffuser and two blower speeds. We visualized in scattered light the deflection of a vertical mist spray cone from a sneeze-simulating nebulizer parallel to the side of the air purifier. We found a significant difference in airflow velocities for different angles to the circumferential outflow diffuser: 0.01–0.02 m/s for 0° vs. 0.01–0.65 m/s for 45° at 1 m distance. We observed no significant deflection of the sneeze-simulating spray cone at the minimum blower speed and a 5 cm deflection at the maximum speed. The deflection of the sneeze-simulating spray mist particles by the tested indoor air purifier with the circumferential outflow, under the experimental conditions, is low relative to the recommended safer distances between people in indoor spaces. We conclude that indoor air purifiers with circumferential outflow diffusers have a lower potential to spread infectious aerosols in indoor spaces compared to devices with unidirectional outflow.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.240
Threshold uncertainty score0.272

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.254
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueAtmosphereSame topicInfection Control and VentilationFrench-language works237,207