Abstract

fetched live from OpenAlex

Airborne particles containing pathogens such as bacteria (e.g., M. tuberculosis) or virions (e.g., influenza or severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)) can cause infections. It has been speculated that the outflow from indoor air purifiers with a directional outlet could entrain and spread pathogen-containing aerosol particles. To date, only the case of indoor air purifiers with a directional outflow has been considered, and here we investigate an indoor air purifier with a circumferential outflow diffuser—an alternative design solution that is already commercially available. We measured the airflow velocity at two different angles to the surface of the circumferential outflow diffuser and two blower speeds. We visualized in scattered light the deflection of a vertical mist spray cone from a sneeze-simulating nebulizer parallel to the side of the air purifier. We found a significant difference in airflow velocities for different angles to the circumferential outflow diffuser: 0.01–0.02 m/s for 0° vs. 0.01–0.65 m/s for 45° at 1 m distance. We observed no significant deflection of the sneeze-simulating spray cone at the minimum blower speed and a 5 cm deflection at the maximum speed. The deflection of the sneeze-simulating spray mist particles by the tested indoor air purifier with the circumferential outflow, under the experimental conditions, is low relative to the recommended safer distances between people in indoor spaces. We conclude that indoor air purifiers with circumferential outflow diffusers have a lower potential to spread infectious aerosols in indoor spaces compared to devices with unidirectional outflow.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.254
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueAtmosphereSame topicInfection Control and VentilationFrench-language works237,207