MétaCan
Menu
Back to cohort
Record W4387529137 · doi:10.1161/hyp.80.suppl_1.p111

Abstract P111: Comparison Of Automated Office Blood Pressure And Self-Measured Blood Pressure: Results From An Ongoing Self-Measured Blood Pressure Program

2023· article· en· W4387529137 on OpenAlexaff
Rosemary Farahmand, Jennifer Cluett, Laken Barkowski, Marc L Cohen, Jonathan X. Li, Ruth Olowoyeye, Raj Padwal, Michael Rakotz, Elisabeth Russo, Neha Sachdev, Katherine Tighe, Stavros Tsipas, Hannah Walley, Peter S Wood, Gregory Wozniak, Stephen P. Juraschek

Bibliographic record

VenueHypertension · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiovascular and Diving-Related Complications
Canadian institutionsNorth American Construction Group (Canada)University of Alberta
Fundersnot available
KeywordsMedicineBlood pressureConcordanceInternal medicineReferralSurgery

Abstract

fetched live from OpenAlex

Background: HTN treatment based on AOBP lowers risk of CVD. SMBP has been promoted as an alternative to AOBP that could improve access and achieve more timely BP control. However, questions remain about the concordance between SMBP and AOBP. Objective: To compare SMBP and AOBP measurements in a 6-month SMBP program. Methods: In this quality improvement study, we examined data from an ongoing SMBP pilot program in a large general medicine practice in Boston. Referred patients underwent AOBP during an initialization clinic visit and then performed SMBP for a week each month over a 6 month period. During the 6 th month of the program, patients performed a final week of SMBP and returned to clinic for an AOBP assessment. We compared the 6 th month mean BPs via paired t-tests. Results: Of 129 patients referred, 74 underwent an initialization visit and at least 1 month of monitoring (mean age 59±13, 53% female, 28% Black). The mean referral BP was 140±11/84±11 mm Hg. In contrast, during program initialization, mean AOBP was 131±13/79±10 (difference compared to referral BP was -9/-5 mm Hg; P <0.001 for both). The mean BP measured the month after initialization using the 1-week SMBP protocol was 133±12/83±7 (difference compared to AOBP was +2/+4; P =0.18 for SBP; P <0.001 for DBP). For the 12 patients that completed 6-months thus far, mean AOBP at the 6-month visit was 127±10/76±8. The mean BP the week of SMBP during the 6 th month of the program was 124±9/79±5 (difference compared to 6-month AOBP was -3/+2 mm Hg; P >0.05 for both) ( Figure ). Conclusion: BP measures from SMBP tracked well with in-office AOBP measurements. These findings add to existing evidence that SMBP might be used in lieu of AOBP for HTN management.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Other · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.012
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.280
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreOther

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueHypertensionSame topicCardiovascular and Diving-Related ComplicationsFrench-language works237,207